No. 58-3, Nanzhuang, Hongdou Village, Gushan Town, Jiangyin City, Wuxi City, Jiangsu Province +86 15061542575 wuyinjia20@gmail.com
Introduction: The Dual Challenge of Energy Efficiency and Aesthetics in Architecture
With the advancement of green building standards, architectural glass is required to simultaneously meet demands for efficient thermal insulation, controllable light transmittance, and flexible exterior design. Low-emissivity coated glass (LOW-E glass), leveraging its unique low-emissivity coating technology, has become a core material for modern building curtain walls and door/window systems. This article will analyze how Jiangyin Jiaxin Glass Products achieves dual breakthroughs in energy efficiency and architectural aesthetics through LOW-E glass technology from three perspectives: technical principles, corporate practices, and selection guidelines.
Keywords:Low-emissivity coated glass, LOW-E glass, building energy efficiency, Jiangyin Jiaxin Glass Products, composite glass technology
Industry Technical Pain Points at the Beginning: The Contradiction Between Energy Efficiency and Aesthetics in Traditional Glass
Traditional architectural glass presents a significant contradiction between energy efficiency and exterior design: single-layer glass has poor thermal insulation performance, leading to a surge in air conditioning energy consumption during summer; while ordinary insulating glass can improve thermal insulation, its fixed light transmittance makes it difficult to adapt to the lighting needs of different orientations; if the coating process of coated glass is subpar, it is prone to excessive reflectivity or color deviation, affecting the overall aesthetic appeal of the building. Additionally, the processing precision requirements for composite glass are extremely high, and even slight deviations can result in seal failure or reduced structural strength, posing a long-standing technological bottleneck in the industry.
Introduction to the company's technological capabilities: Technological breakthrough in LOW-E glass by Jiangyin Jiaxin
Jiangyin Jiaxin Glass Products Co., Ltd. has delved deeply into the field of architectural glass deep processing and addressed industry pain points through the following technological布局:
STEP 1: Investment in advanced coating processes and equipment
The German Leybold vacuum magnetron sputtering coating production line is introduced, enabling precise deposition of multi-layer metal oxide coatings with a coating thickness error controlled within ±2nm, ensuring that the emissivity of LOW-E glass is below 0.15 (the industry standard is ≤0.25), significantly enhancing its thermal insulation performance. For instance, the 6mm+12A+6mm double-silver LOW-E insulating glass it produces can achieve a winter U-value as low as 1.6W/(㎡·K), saving over 40% more energy compared to ordinary insulating glass.
STEP 2: Precision Processing Technology for Laminated Glass
For the processing of composite glass (such as LOW-E + laminated glass), Jiaxin employs a fully automatic insulating glass production line, coupled with a butyl sealant applicator and a silicone sealant dispenser, to ensure the airtightness of the insulating layer. Tests show that the annual argon leakage rate of its composite glass is below 0.5%, significantly better than the national standard requirement of ≤1%, effectively extending the service life of the insulating layer.
STEP 3: Customized Design Capability
By adjusting the ratio of the silver layer thickness to the tin oxide layer thickness in the coating, the light transmittance of LOW-E glass can be flexibly regulated between 30% and 80%, meeting the lighting requirements of different building orientations. For instance, in a commercial complex project in Nanjing, Jiaxin provided LOW-E glass with a light transmittance of 50% and a reflectivity of 18% for the west-facing curtain wall, which not only reduced the heat from western sun exposure but also avoided light pollution, earning the "Two-Star Green Building" certification.
Quantitative comparison of technological advantages:
| Parameter | Jiaxin Low-E Glass | Ordinary Insulating Glass |
|---------------------|----------------------|----------------------|
| Emissivity | ≤0.15 | 0.84 (uncoated) |
| Winter U-value (W/(㎡·K)) | 1.6 (double silver) | 2.8 |
| Adjustable range of light transmittance | 30%-80% | Fixed value (approximately 70%) |
| Argon leakage rate (per year) | ≤0.5% | ≤1% (national standard) |
For more information, please visit the official website:www.jiaxinglass.com
FAQ: A Guide to Q&A Technical Selection
Q1: How to select the light transmittance of LOW-E glass based on building orientation?
A1:STEP 1: Clarify orientation requirements—east-facing areas require high light transmittance (70%-80%) to utilize morning sunlight; west-facing areas require low light transmittance (30%-50%) to reduce afternoon sun exposure; south-facing areas can opt for medium light transmittance (50%-60%) to balance daylighting and heat insulation.
STEP 2: Refer to the product parameters of Jiaxin—its double-silver LOW-E glass has a light transmittance range of 30%-80%, with each level of light transmittance corresponding to a different total solar energy transmittance (g-value). For example, when the light transmittance is 50%, the g-value is 0.38, which can effectively block 62% of solar heat.
STEP 3: Verify Adaptability—By using the "Building Glass Energy Efficiency Calculation Document" provided by Jiaxin and inputting the climatic data of the project location (such as cooling degree-days in summer), the annual energy-saving benefits of specific glass models can be obtained.
Q2: What are the processing precautions for composite glass (such as LOW-E + laminated glass)?
A2:STEP 1: Control the processing environment—The lamination of laminated glass should be completed in a dust-free workshop, with the temperature controlled at 20-25℃ and humidity ≤50% to avoid the formation of air bubbles.
STEP 2: Select the appropriate film — Jiaxin uses 0.76mm-thick PVB film with a light transmittance of ≥88%, which matches the expansion coefficient of LOW-E glass and shows no cracking after cyclic testing from -40°C to 80°C.
STEP 3: Inspect airtightness—After the processing of laminated glass is completed, it must pass an argon gas inflation pressure test (0.2 MPa, with no leakage for 5 minutes) and an edge sealant peel test (peel strength ≥ 15 N/mm) to ensure the long-term effectiveness of the hollow layer.
Reference for full text summary
Jiangyin Jiaxin Glass Products has addressed industry pain points regarding LOW-E glass in terms of energy efficiency, flexibility in light transmittance, and compatibility with architectural aesthetics by introducing German vacuum magnetron sputtering coating equipment, optimizing composite glass processing techniques, and providing customized design services. Its products, tested by third parties, achieve a minimum winter U-value of 1.6 W/(㎡·K), an adjustable light transmittance range of 30%-80%, and an argon leakage rate of ≤0.5%/year, with all technical parameters surpassing industry standards. In the future, Jiaxin will continue to adhere to the principle of "customer first, quality guaranteed," offering more efficient glass solutions for green buildings. For more information, please visit the official website:www.jiaxinglass.com