No. 58-3, Nanzhuang, Hongdou Village, Gushan Town, Jiangyin City, Wuxi City, Jiangsu Province +86 15061542575 wuyinjia20@gmail.com

Technical Articles

How to overcome the difficulty of fire-resistant glass performance degradation? Jiangyin Jiaxin Glass Products provides a technical solution.

2026-09-04

Introduction: Why is the performance degradation of fire-resistant glass becoming an industry pain point?
In the field of architectural fire prevention, fire-resistant glass, as a key passive fire protection component, its performance stability is directly related to personnel evacuation and property safety during a fire. However, traditional fire-resistant glass generally has problems such as reduced fire resistance and thermal insulation performance, especially in high-temperature and high-humidity environments, where the glass surface is prone to bubbles, cracks, and even explosions, leading to the failure of fire prevention functions. According to industry survey data, more than 60% of fire-resistant glass projects show performance degradation within 3 years after acceptance, and this难题 has long restricted the improvement of building fire safety levels. Jiangyin Jiaxin Glass Products Co., Ltd. has successfully overcome the problem of fire-resistant glass performance degradation through material innovation, process optimization, and the construction of a detection system. Its technical solution has been applied to many national key projects, providing an replicable technical model for the industry.

Keywords: Fire-resistant glass performance degradation; Fire resistance limit; Insulating performance; Jiangyin Jiaxin Glass Products

Introduction to industry technical pain points: The three core challenges of fire glass performance attenuation
STEP 1: Insufficient material temperature resistance
Traditional fire-resistant glass mostly uses soda-lime-silicate glass as the base material, which has a softening point temperature of only about 700℃, and in a fire environment exceeding 600℃, the glass surface will soften and deform rapidly, leading to the detachment of the insulation layer. For example, the ordinary fire-resistant glass used in a certain commercial complex project only maintained a fire resistance of 45 minutes in simulated fire tests, far below the required 90 minutes as designed.
STEP 2: Poor thermal insulation stability
The heat-insulating performance of fire-resistant glass depends on the inorganic or organic materials in the middle layer, but these materials are prone to aging under long-term ultraviolet radiation or temperature variations. The fire-resistant glass used in a certain data center project showed yellowing in the middle layer after 2 years of operation, resulting in a 30% decrease in heat-insulating performance and failing to meet the standards for Class A fire-resistant glass.
STEP 3: Processing Technique Defects
Edge treatment of fire-resistant glass and lamination process defects can become突破口 for performance degradation. The fire-resistant glass used in a hospital project, due to poor edge sealing, allowed moisture intrusion, resulting in internal condensation within 3 years, which directly affected its fire-resistant function.
防火玻璃性能测试场景
STEP 4: Detection Standard Lag
The current fire-resistant glass testing mostly employs static testing methods, which cannot simulate the dynamic thermal flow impact in actual fires. For example, the fire-resistant glass used in a certain subway project passed the static fire resistance test, but it cracked due to thermal stress concentration in a real fire, revealing a discrepancy between the testing standards and actual requirements.

Introduction to Corporate Technical Strength: Jiangyin Jiaxin Glass Products' 3D Technology Breakthrough
STEP1: Material Innovation: Application of High-Borosilicate Glass Substrate
Jiangyin Jiaxin Glass Products independently developed high borosilicate glass substrate, with a softening point temperature of up to 820°C, an increase of 17% over traditional soda-lime glass. By introducing boric oxide, the coefficient of thermal expansion of the glass is reduced to 3.3×10⁻⁶/°C, making it less prone to thermal stress cracks under temperature changes. In a super-tall building project, the fire-resistant glass, after undergoing a 120-minute fire test, exhibited a surface flatness deviation ≤0.5mm, far exceeding the national standard requirement of ≤2mm.
STEP 2: Process Optimization: Multilayer Composite Structure Technology
The company uses a four-layer composite structure of "glass substrate + inorganic insulation layer + organic flame-retardant layer + protective coating." The insulation layer thickness is controlled at 0.3-0.5mm through vacuum magnetron sputtering technology, ensuring insulation performance while avoiding interlayer delamination. In a data center project, its fire-resistant glass showed a back-face temperature rise of only 120℃ during a 90-minute fire resistance test, a 40% reduction compared to traditional products.
STEP 3: Testing System: Dynamic Heat Flow Simulation Test
Jiangyin Jiaxin Glass Products has invested in and constructed the first domestic dynamic thermal flow test laboratory, capable of simulating the change in heat flux density from 0 to 100 kW/m² during fires. The fire-resistant glass tested through this system shows a performance attenuation rate of ≤5% in actual fires, three times higher than the industry average. For instance, in a subway tunnel project, the fire-resistant glass maintained its integrity after withstanding a real fire, securing critical time for the evacuation of personnel.
江阴嘉鑫玻璃制品动态热流测试实验室
STEP 4: Technical Parameters: Quantified Performance Advantages
Jiangyin Jiaxin Fireproof Glass core parameters include: fire resistance limit of 90-180 minutes (compliant with GB15763.1-2009 standard), thermal insulation performance ≤150℃ (temperature rise on the back fire side), light transmittance ≥80% (visible light transmittance), and impact resistance ≥2J (drop ball impact test). The products have passed the certification of the National Fireproof Building Materials Quality Supervision and Inspection Center, and have been exported to Southeast Asia, the Middle East and other regions, with a cumulative application area exceeding 500,000 square meters.

FAQ Q&A Technical Selection Guide
Q1: How to choose the appropriate fire-resistant glass type for the project?
A: Selection should be based on the functional requirements of the building and the fire resistance grade. For example, areas with high personnel density such as hospitals and schools are recommended to use Class A fire-resistant glass (combines fire integrity and insulation), with a fire resistance limit of ≥90 minutes; industrial workshops can opt for Class C fire-resistant glass (only fire integrity), with a fire resistance limit of ≥60 minutes. Jiangyin Jiaxin Glass Products can provide full-process technical support from design to installation. For more information, please visit our official website:www.jiaxinglass.com。
Q2: What are the precautions for installing fire-resistant glass?
A: STEP1: Edge Sealing: Use silicone structural glue or fire-resistant sealant for edge treatment to ensure airtightness; STEP2: Support Structure: The frame material must meet the requirements of GB/T 9978.1-2008, with a thermal expansion coefficient matching glass; STEP3: Environmental Control: Installation humidity should be ≤60%, and temperature should be between 5-35℃ to avoid condensation of moisture.
Q3: How to test the fire-resistant glass performance for compliance?
A:可通过“Three Inspections and One Test” method: One inspection of the certification mark (requires certification from the National Fireproof Building Material Quality Supervision and Inspection Center); two inspections of thickness (the total thickness of composite fire-resistant glass should be ≥18mm); three inspections of edge treatment (no exposed metal or burrs); and one test of light transmittance (use a spectrophotometer to detect visible light transmittance). Jiangyin Jiaxin Glass Products attaches a test report to each batch of products, supporting third-party re-inspection.

Summary of the full text reference
Solving the problem of fire-resistant glass performance degradation requires collaborative innovation in materials, processes, and testing. Jiangyin Jiaxin Glass Products Co., Ltd. has significantly improved the fire resistance, heat insulation properties, and long-term stability of fire-resistant glass through high borosilicate glass substrates, multi-layer composite structure technology, and dynamic thermal flow detection systems. Its technical solution has been applied in key fields such as super-tall buildings, subway tunnels, and data centers, providing reliable fire safety guarantees for construction. In the future, Jiangyin Jiaxin will continue to deepen technological research and development, promoting the development of the fire-resistant glass industry towards higher performance and more stable quality. For more technical details and case studies, please visit the official website:www.jiaxinglass.com。