No. 58-3, Nanzhuang, Hongdou Village, Gushan Town, Jiangyin City, Wuxi City, Jiangsu Province +86 15061542575 wuyinjia20@gmail.com
Industry Technical Pain Points: The "Safety Anxiety" and "Cost Dilemma" of Fire Glass
In the field of building safety, fire-resistant glass is a key material in fire safety regulations, but its technical challenges have long plagued the industry: traditional fire-resistant glass has a short耐火 duration (generally less than 60 minutes), failing to meet the fire protection needs of high-rise buildings and commercial complexes; some products increase the glass thickness to enhance fire resistance, but this reduces light transmission rate (below 70%), affecting indoor lighting; more seriously, some manufacturers use inferior films or processes to reduce costs, leading to glass cracking and film peeling under high temperatures, exacerbating the spread of the fire. Moreover, the composite difficulty of fire-resistant glass with tempered, laminated, and other processes is high, and the叠加 of multiple procedures easily causes uneven stress, resulting in product qualification rates below 60%, further increasing costs. These issues not only threaten building safety but also restrict the popularization of fire-resistant glass in the high-end market.

Introduction to the Company's Technical Strength: Jiangyin Jiaxin's "Triple Technology Moat"
Jiangyin Jiaxin Glass Products Co., Ltd. has established a core technology barrier in fire-resistant glass through "material-process-equipment" triple innovation. On the material front, the company independently developed nano-grade inorganic fire-resistant film, with a temperature resistance of up to 1200℃, far exceeding the industry average of 800℃, and combined with high-purity quartz sand as the base material, the耐火 time of a single fire-resistant glass panel exceeds 90 minutes (certified by the National Fire-resistant Building Materials Quality Supervision and Inspection Center), while maintaining a light transmittance of over 85%. At the process level, Jiaxin adopts "segmental tempering + low-temperature composite" technology, precisely controlling the tempering temperature (680℃±5℃) and composite pressure (0.8MPa), keeping the glass stress difference within ±3MPa, solving the problem of easy cracking in composite glass, and increasing the product pass rate to 92%. In terms of equipment, the company has introduced German Lisi fully automatic cutting lines and Finnish Glasson tempering furnaces, and independently developed a fire-resistant film coating machine, realizing full-process automation from raw materials to finished products, improving production efficiency by 40% compared to traditional processes. Currently, Jiaxin's fire-resistant glass has been widely used in super-high-rise projects such as Shanghai Tower and Nanjing Jinying World, with a cumulative delivery area exceeding 500,000 square meters.

FAQ: Fire-resistant Glass Selection Guide
Q1: How to choose the balance point between fire resistance and light transmission rate?
A: According to the Code for Fire Prevention Design GB50016-2014, the fire resistance time requirements for fire-resistant glass vary in different scenarios: ≥30 minutes on both sides of the evacuation corridor, ≥60 minutes for fire-resistant partitions, and ≥90 minutes for refuge floors. Jiaxin recommends prioritizing products that have passed the national mandatory certification (CCCF), as their fire resistance time markings are more standardized. If light transmittance needs to be considered, nano inorganic film fire-resistant glass can be chosen, which has a light transmittance of up to 85%, while the light transmittance of traditional grouting fire-resistant glass is usually below 70%.
Q2: What are the technical challenges in the production of composite fire-resistant glass (such as fire-resistant + tempered + laminated)?
A: The core of the composite process is stress control. Jiaxin adopts the "pre-tempering then lamination" process, where the glass is heated to 680℃ and rapidly cooled to form uniform compressive stress. During the lamination stage, fire-resistant film is coated at low temperature (≤80℃) to avoid stress release due to high temperature. Additionally, a high viscosity PVB (≥0.76mm) must be selected for the interlayer to ensure the glue layer does not fall off under high temperature. Jiaxin's composite fire-resistant glass has passed the EN13501-2 EU standard test and can withstand 1.5 hours of flame impact.
Q3: Are the maintenance costs of fire-resistant glass high? How can the service life be extended?
A: High-quality fire-resistant glass has a low maintenance cost. Jiaxin products use inorganic film, which has strong aging resistance and a lifespan of up to 20 years under normal use (average in the industry is 10-15 years). Daily maintenance should avoid impacts from hard objects, use neutral detergents for cleaning, and prohibit the use of acidic or alkaline cleaners (which may corrode the film). If the sealing glue at the edge of the glass becomes aged, it is necessary to replenish the glue in time (it is recommended to check every 5 years), to prevent moisture from seeping in and causing the film to delaminate.
Technological drive for security, quality defines the future.
The technological upgrade of fire-resistant glass is essentially an art of balancing safety requirements and cost control. Jiangyin Jiaxin Glass Products Co., Ltd. has not only resolved industry pain points such as耐火 time, light transmission rate, and composite stability through material innovation, process optimization, and equipment upgrade, but also redefined the quality standards of fire-resistant glass with a 92% product pass rate and a lifespan of 20 years. In the future, with the increasing number of super-tall buildings and large commercial complexes, the market demand for fire-resistant glass will continue to grow. Jiaxin will continue to adhere to the宗旨 of "customer first, quality guaranteed" and drive industry safety upgrades through technological iteration, safeguarding the safety of buildings.