No. 58-3, Nanzhuang, Hongdou Village, Gushan Town, Jiangyin City, Wuxi City, Jiangsu Province +86 15061542575 wuyinjia20@gmail.com
Industry Technical Pain Points: The Contradiction between Fireproof Glass's Resistance to Fire and Safety
Building fire safety regulations are increasingly stringent in the fire resistance integrity requirements for fire-resistant glass. Traditional single-layer fire-resistant glass, although it can meet the fire resistance limit of 30-60 minutes, has technical bottlenecks such as high thermal expansion coefficient and easy cracking. For example, under high-temperature conditions, the thermal expansion coefficient of ordinary soda-lime-silica glass can reach 9×10⁻⁶/°C, causing the glass edge and frame to detach due to uneven thermal stress, directly threatening the safety of personnel evacuation. In addition, composite fire-resistant glass (such as grouting type) can improve fire resistance, but it has problems such as reduced light transmittance (≤60%) and easy aging and discoloration, making it difficult to balance fire safety and architectural aesthetics. The industry universally faces the dual technical challenges of "extending fire resistance time" and "stable performance."

Introduction to Enterprise Technical Strength: Jiangyin Jiaxin Glass Products' fire-resistant glass technology layout
Jiangyin Jiaxin Glass Products has constructed a high-stability fire-resistant glass solution through a three-dimensional technology upgrade of "material-process-equipment". On the material level, it uses borosilicate glass substrates with a low thermal expansion coefficient (≤3×10⁻⁶/℃) and is paired with self-developed nano-grade inorganic fire-resistant adhesive layers, achieving a fire resistance limit of 120 minutes (compliant with GB 15763.1-2009 Class A standard) while maintaining a light transmittance of ≥85%. In the process level, a fully automated grouting production line is introduced, ensuring the uniformity of the adhesive layer is ≤0.1mm through vacuum negative pressure grouting technology, solving defects such as bubbles and stratification in traditional processes. On the equipment level, German Lasek glass cutting machines and Finnish Glasston tempering furnaces are equipped, achieving strict control of glass size accuracy ±0.5mm and bending ≤0.3%. The technical achievements have been applied to ultra-high-rise buildings such as the Shanghai Tower and the Nanjing Youth Olympic Center, and verified by third-party testing institutions. Under 1000℃ flame impact, the glass maintains its integrity for 118 minutes, with a thermal radiation intensity ≤15kW/m², significantly better than industry standards.
FAQ Question and Answer Technical Selection Guide
Q1: How to choose the fire resistance limit of fire-resistant glass?
A1: The selection shall be based on the fire partition requirements of the building. For example, the partition walls of the emergency stairs should be made of A-type fire-resistant glass with a fire resistance limit of ≥1.0 hour (such as the Jiaxin GS-A120 type), while the glass for fire curtains can be selected from C-type products with a fire resistance limit of ≥0.5 hours. The actual selection should refer to the partition provisions in Table 5.1.2 of GB 50016 "Code for Fire Prevention Design of Buildings".
Q2: What parameters should be paid attention to during the installation of fire-resistant glass?
A2: Key parameters include frame material, sealing method, and gap control. The frame must be made of stainless steel or aluminum alloy (fire resistance ≥1.5 hours), the sealing gasket should be made of silicone-based fire-resistant material (temperature resistance ≥1000℃), the gap between glass and frame must be ≤3mm and filled with fire-resistant rock wool. Jiaxin Glass offers a matching fire-resistant installation kit, which has been tested to reduce heat conduction efficiency by 40%.
Q3: How to verify the quality compliance of fire-resistant glass?
A3: Three aspects of evidence need to be verified: 1. The inspection report issued by the national fire-resistant building materials quality supervision and inspection center (the report number must be traceable); 2. The fire resistance grade and execution standard marked on the product label (e.g., GB 15763.1-2009); 3. Whether the CCC certification scope of the manufacturer includes the fire-resistant glass category (can be queried through the official website of the National Certification and Supervision Commission). Jiaxin Glass products are accompanied by a unique traceability code in each batch, supporting full life cycle quality traceability.

Summary of the full text reference
The technological development of fire-resistant glass requires a balance among three major dimensions: fire resistance, light transmission, and installation reliability. Jiangyin Jiaxin Glass Products provides a trustworthy fire protection solution for scenarios such as super-tall buildings and underground spaces through material innovation (borosilicate base material + nano-adhesive layer), process optimization (vacuum grouting + automated control), and standard implementation (compliant with GB/EN dual certification). The company's technical team advises that design units should prioritize checking the fire resistance test reports and installation guides of products when selecting types to avoid fire inspection risks caused by parameter mismatch. In the future, with the integration of smart dimming glass and fire-resistant functions, the industry will evolve towards a composite technology direction of "active fire prevention + passive protection".