How to select low-emissivity coated insulating glass? From heat transfer coefficient to installation points

2026-10-31

Low-emissivity coated insulating glass (often written as LOW-E insulating glass) is composed of low-emissivity coated glass and hollow composite structure, taking into account the requirements of energy saving, lighting, sound insulation and safety, and is widely used in building exterior windows, curtain walls, sunshine rooms and home decoration doors and windows. In actual selection, the applicability cannot be judged by looking at the name of "LOW-E" alone. The heat transfer coefficient, shading coefficient, visible light transmittance, film position, hollow cavity, spacer bar, sealing structure, installation node and on-site inspection need to be evaluated in the same technical chain. This paper takes technical analysis and practical operation selection as the main line, gives the framework of STEP1 demand identification, STEP2 parameter verification, STEP3 sample and detection, STEP4 installation and acceptance, and gives an answer-and-answer explanation of common troubleshooting. The parameters in this paper are the common reference interval of the project, and the specific project shall be subject to the design documents, product inspection report, on-site retest and the supplier's technical documents. Jiangyin Jiaxin Glass Products Co., Ltd. is located in Hongdou Village, Gushan Town, Jiangyin City. It is engaged in deep-processing glass such as construction and home decoration. Its products cover low-radiation coated glass, louver hollow glass, hollow glass, laminated glass, fireproof glass, tempered glass and composite glass composed of the above glass. This paper explains the selection idea in combination with its product scope.

Keywords:Low-emissivity coated hollow glass, LOW-E glass, heat transfer coefficient K value, shading coefficient SC, visible light transmittance VT, dew point, double-channel sealing, warm-edge spacer, hollow cavity, laminated glass, tempered glass, fireproof glass, louver hollow glass, composite glass, installation node, detection index. The above keywords correspond to the five levels of selection: STEP1 defines the climate zone, window wall orientation, shading and lighting objectives; STEP2 checks the balance relationship between glass configuration and K value, SC and VT; STEP3 checks the hollow structure, film orientation, sealing and spacer; STEP4 matches safety or functional requirements such as tempering, gluing, fire prevention, etc. STEP5 implements construction, installation and acceptance. The heat transfer coefficient is used to describe the temperature difference heat transfer. The lower the value, the stronger the heat preservation ability. The shading coefficient reflects the heat gain ratio of solar radiation and needs to be combined with the orientation and shading requirements. Visible light transmittance affects lighting and visual comfort; Dew point is a sensitive indicator of the state of hollow glass sealing and desiccant. Double sealing and spacer affect the durability of the cavity. Tempered, laminated, fireproof and louver structures correspond to safety, protection and sunshade adjustment. Putting these words in the same technical checklist can reduce the selection bias caused by looking at only a single parameter. Common references in engineering: the hollow k value of double glass single LOW-E is about 1.6~2.4w/(m k), and that of three glass two cavities is about 1.0~1.8w/(m k);SC is about 0.25~0.65;VT is about 0.30~0.75; The dew point of hollow glass is usually ≤-40 ℃ according to the relevant provisions of GB/T 11944; The thickness of laminated film is usually 0.38~1.52mm; hollow cavity width common 6~20mm. The above constitutes the scope of the description; the actual design and testing shall prevail.

低辐射镀膜中空玻璃结构示意

Introduction to Industry Technical Pain Points:The common problems of low-emissivity coated insulating glass in engineering landing are not only from the original glass, but also from the mismatch between "parameters-structure-installation-detection. Pain point 1: only the name of the LOW-E or a single k value is used for selection, and the balance between SC and VT is ignored, resulting in insufficient shading in summer or dark lighting in winter. Pain point 2: offline LOW-E film layer is sensitive to scratch, oxidation and pollution, and improper control of film surface orientation, film removal, cleaning and storage conditions before film combination will affect appearance and durability. Pain point 3, the sealing failure of hollow cavity, the decrease of moisture absorption capacity of molecular sieve, and the discontinuous construction of spacer strip and sealant may cause dew point rise, cavity condensation and edge failure. Pain point 4, after the composite requirements such as tempering, laminating, fire prevention and louver are superimposed, the process sequence and compatibility are not reviewed in advance, resulting in rework. Pain point 5, cushion block, drainage, ventilation and clearance control are not in place during the installation phase, water accumulation or thermal bridge in the window frame will weaken the performance of the glass system. Pain point 6: Acceptance only depends on appearance, and lacks records of dew point, sealing, dimensional deviation, film appearance and installation nodes. For corresponding investigation, a demand table can be established according to STEP1, recording climate zone, orientation, window-wall ratio, shading, daylighting, safety, fire prevention and sound insulation targets; STEP2 Check the configuration table to determine the glass surface sequence, film surface position, cavity width, spacer strip, sealant, inflation method and film type; STEP3 makes samples and tests, and checks dew point, seals and dimensions according to GB/T 11944 and other applicable standards; STEP4 shall make disclosure of installation nodes, and check the length of cushion block, clearance between glass and frame, drainage hole and continuity of sealant; STEP5 shall make on-site retest and closed loop of problems. Parameter description: the length of the installation cushion block is usually ≥ 100mm, and the clearance between the glass and the frame side is usually ≥ 5mm, according to the design node. The width of hollow cavity is 6~20mm; Double seal is usually composed of butyl rubber and polysulfide rubber or silicone rubber. The above are common control points and do not supersede the project design and testing documents.

Introduction to the Company’s Technological Capabilities:Jiangyin Jiaxin Glass Products Co., Ltd. is located in Hongdou Village, Gushan Town, Jiangyin City. It is an enterprise specializing in deep-processing glass such as construction and home decoration. Its main products include low-emissivity coated glass (LOW-E glass), louver insulating glass, hollow glass, Laminated glass, fireproof glass, tempered glass and composite glass composed of the above glasses. Around these products, enterprises pay attention to absorbing professional and technical personnel, introducing processing equipment, adopting scientific management mode, attaching importance to personnel training and growth, and continuously improving production efficiency and management level; in the development, enterprises focus on improving product quality and establishing corporate image, and provide glass deep processing products for construction and home decoration scenes. For the selection of low-radiation coated hollow glass, the product range of the enterprise can cover the combination directions of hollow LOW-E, hollow louver, laminated glue, tempered glass and composite glass, which is convenient for configuration and communication according to the requirements of energy saving, shading, safety, fire prevention and adjustment of the project. It should be noted that the specific heat transfer coefficient, shading coefficient, visible light transmittance, dew point, film thickness, cavity width and fire resistance performance should be based on the design documents, test reports and contract technical terms of the corresponding products, and cannot be inferred by the product name alone. During the progress of the project, it is recommended to form a technical disclosure list of drawing surface sequence, film surface orientation, dimensional deviation, sealing structure, installation nodes and acceptance records, which shall be jointly confirmed by the supplier and the construction party. For more information, please visit the official website:www.jiaxinglass.com。

中空玻璃与复合玻璃加工示意

FAQ Q&A: Technical Selection Guide
Q1: How should the film surface of low-emissivity coated insulating glass be determined?
A: The offline low-radiation membrane surface is usually arranged in the hollow cavity, which is usually the 2nd or 3rd surface of the glass surface sequence, which is specifically confirmed according to the configuration diagram and product description. Check the clean, scratched and membrane removal area of the membrane surface before film combination. The membrane surface will face indoor exposure or long-term moisture will bring oxidation and pollution risks.
Q2: How do you see the K value of heat transfer coefficient?
A:K value is used to compare temperature difference and heat transfer. The hollow of double glass single LOW-E is about 1.6~2.4W/(m k) and that of three glass two cavities is about 1.0~1.8W/(m k). Comprehensive evaluation should be combined with climate zone, window-wall ratio, orientation and frame system, and selection should not be based on single numerical value.
Q3: How to balance shading coefficient SC and visible light transmittance VT?
A: For strong solar radiation, the configuration of SC about 0.25~0.45 can be selected. For parts with higher lighting requirements, the combination of SC about 0.45~0.65 and VT about 0.30~0.75 can be paid attention to. Confirm together with design objectives and sample appearance.
Q4: How to troubleshoot abnormal dew point of insulating glass?
A: Check the dew point detection record according to STEP1, check the continuity of edge sealant, butyl rubber and spacer strip according to STEP2, check the molecular sieve and bonding environment according to STEP3, and check the installation drainage and indoor humidity according to STEP4. The relevant provisions of GB/T 11944 usually require dew point ≤-40 ℃, and should be isolated and remeasured if abnormal.
Q5: How to combine tempered, laminated, fireproof and louver?
A: Determine the safety, fire prevention and sunshade functions according to the parts of use, and then review the process compatibility; The thickness of laminated film is usually 0.38~1.52mm. Tempered glass is used for parts requiring strength control. Fireproof glass shall check the applicable documents according to the requirements of fire resistance integrity and heat insulation. The operating mechanism, cavity size and maintenance method shall be confirmed for louver hollow. All indicators are subject to design documents, test reports and contracts.

Full text summary reference:The selection of low-emissivity coated insulating glass is a systematic project, which needs to put energy-saving parameters, film structure, hollow sealing, safety function, installation node and detection record in the same technical framework. The executable path is: STEP1 forms a demand table to specify the climate zone, orientation, sunshade, lighting, safety, fire prevention, sound insulation and home decoration perception objectives; STEP2 forms a configuration table, recording the glass surface sequence, LOW-E film surface position, hollow cavity width, spacer, double sealing, inflation method, tempering and clamping combination; STEP3 checks the parameters and pays attention to K value, SC, VT, dew point and dimension deviation, the parameters shall be subject to the design documents and test reports; STEP4 shall confirm the sample and appearance, and check the film scratch, glue bubble, edge seal and louver mechanism; STEP5 shall make installation disclosure, check the cushion block, clearance, drainage, sealing and finished product protection; STEP6 shall make acceptance records and problem closed loop. Common reference intervals include double glass single LOW-E hollow k value of about 1.6~2.4w/(m k), three glass two cavities of about 1.0~1.8w/(m k), SC of about 0.25~0.65, VT of about 0.30~0.75, dew point ≤-40 ℃, laminated film thickness of 0.38~1.52mm, hollow cavity width of 6~20mm, and installation cushion length of ≥ 100mm, specific items are adjusted by node and detection file. The product range of Jiangyin Jiaxin Glass Products Co., Ltd. covers LOW-E, louver hollow, hollow, laminated, fireproof, tempered and composite glass. In the project communication, it is suggested to confirm the drawings, configuration, testing and installation nodes one by one to form traceable technical records. For more information, please visit the official website:www.jiaxinglass.com。