No. 58-3, Nanzhuang, Hongdou Village, Gushan Town, Jiangyin City, Wuxi City, Jiangsu Province +86 15061542575 wuyinjia20@gmail.com
[Introduction]The exterior window of the building is not only the lighting port, but also the main channel for heat gain and heat loss. In summer, the solar radiation from westward and southward windows is concentrated, and in winter, it is hoped to retain a certain amount of solar heat. If you only rely on external shading components or fixed coating for shading, you often sacrifice indoor natural lighting while shading, and it is difficult to adjust with seasons and time periods. The louver hollow glass places the adjustable louver blade in the hollow glass sealed cavity, and realizes the turning and lifting of the blade through magnetic control or mechanical transmission, so that the shading coefficient changes from a fixed value to an adjustable value, and at the same time separates the blade from dust and rain, thus reducing the cleaning and maintenance links of the external shading components. This structure puts forward finer requirements for glass deep processing: the width of the blade must match the width of the hollow cavity, the transmission part and the threading part must be sealed, the double-channel sealing between butyl rubber and polysulfide rubber or silicone rubber must be compatible, the gas layer must be stable, the dew point must be controlled within the standard limit, and the turning mechanism must withstand the durability test of repeated operations. This paper takes the calculation and value of shading coefficient as a clue, disassembles layer by layer according to the order of structural composition, thermal parameters, selection and configuration, detection index and troubleshooting, and combines the processing experience of Jiangyin Jiaxin Glass Products Co., Ltd. in the direction of insulating glass, Low-E glass, laminated glass, fireproof glass, tempered glass and composite glass, and gives the technical points for reference in design, procurement and construction.
1. keywordsKey words: louver hollow glass; Shading coefficient SC; Solar heat gain coefficient SHGC; Heat transfer coefficient k; Visible light transmittance τ v;Low-E low radiation coating; Hollow cavity gas layer; Warm edge spacer; Double seal; Dew point; Built-in louver turnover mechanism; Magnetron control transmission; Composite glass. The shading coefficient SC refers to the ratio of the heat gain of solar radiation through the glass member to the heat gain of 3mm thick ordinary transparent glass under the same conditions, which is used to characterize the strength of the shading ability. SHGC ≈ Sc× 0.87 is often used for approximate conversion in engineering. The heat transfer coefficient K represents the heat transfer capacity under the action of temperature difference, and the unit is W/(m · K). The lower the value, the better the performance of winter heat preservation and summer heat insulation. Its value is related to the glass configuration, gas layer thickness and spacer material. The visible light transmittance τv determines the brightness of indoor natural lighting, which usually changes in the same direction as SC, and needs to be adjusted jointly by blade opening and coating parameters. Low-E low-radiation coating reduces radiation heat transfer by reducing the mid-far infrared emissivity, and the position of the film surface will change the radiation heat transfer path between it and the built-in blade. Air or argon is commonly used in the gas layer of the hollow cavity, and the type and concentration of the gas directly affect the K value. Warm-edge spacers are used to reduce edge thermal bridging and mitigate edge condensation. The double-channel seal is composed of butyl rubber and polysulfide or silicone rubber, which determines the gas retention rate and dew point stability. The dew point shall not be higher than -40 ℃ according to the requirements of GB/T 11944. The built-in louver turning mechanism and magnetic control transmission components determine the adjustability and durability of the blades, which is the structural core of the louver hollow glass different from ordinary hollow glass.
2. industry technical pain point opening: six types of constraints when adjustable sunshade landing.1. Conflict between shading and daylighting requirements. The shading coefficient of conventional Low-E hollow glass is mostly in the range of 0.35~0.55, and the visible light transmittance is mostly in the range of 0.40~0.70. Once SC is reduced according to the demand of western sun in summer, indoor lighting will decrease in winter and cloudy days. Although the external sunshade is adjustable, it increases the cost of facade components, cleaning and safety maintenance. 2. Geometric matching of cavity width to blade width. Built-in blades are commonly used in 16mm and 25mm specifications. The width of the hollow cavity needs to leave a gap between turning and lifting. If the cavity is narrow, blade scraping and turning jamming are easy to occur. If the cavity is too wide, the convection of the gas layer will be increased and the heat preservation effect will be weakened. The common cavity widths are 12A, 16A and 20A, which need to be matched with the blade specifications and opening methods. 3. The sealing weak points in the transmission components. Mechanical threading transmission requires a sealed channel between the hollow cavity and the outside. Improper handling of the threading hole will become a channel for water vapor to enter. Magnetron transmission is not perforated, but is sensitive to magnetic coupling distance and blade counterweight. 4. Double-seal system and gas retention. The coating width and thickness of butyl rubber and the curing quality of polysulfide or silicone rubber jointly determine the gas retention rate. Any insufficient sealing will reduce the concentration of argon, the K value will rise, and the dew point may also rise. 5. Inspection and acceptance indicators are incomplete. On-site acceptance pays more attention to appearance, size and dew point, and retests of thermal indexes such as shading coefficient, visible light transmittance and gas concentration are less, resulting in deviation between design value and actual performance. 6. The configuration does not match the orientation. The heat characteristics of the west, east and skylights are different. If the same configuration is adopted uniformly, it is easy to cause insufficient shading in some rooms and dark lighting in some rooms. The above six types of constraints are intertwined, and if only a single parameter is adjusted for selection, there is often a price to be paid for another performance.
Introduction of Technical Strength of 3. EnterprisesJiangyin Jiaxin Glass Products Co., Ltd. is located in Hongdou Village, Gushan Town, Jiangyin City. It is a glass enterprise specializing in deep processing such as construction and home decoration. Its main products include low-emissivity coated glass (Low-E glass), louver hollow glass, hollow glass, laminated glass, fireproof glass, tempered glass and composite glass composed of the above glasses. Around the category of louver hollow glass, the company's processing link covers the cutting and tempering of the original sheet at the front end, the debugging of the hollow sheet, butyl rubber coating, blade assembly and turnover mechanism at the middle section, and the double sealing, gas filling and finished product inspection at the rear section, which can be combined with Low-E coated glass, laminated glass and tempered glass to form a composite structure, adapted to the home decoration sun room, residential windows, office partitions, stairwell lighting roof and other scenes on the sun, lighting, safety and fire protection of the differentiated needs. Jiaxin Glass pays attention to absorbing professional and technical talents, introducing advanced processing equipment, adopting advanced scientific management mode, paying attention to the cultivation and growth of talents, and continuously improving the production efficiency and management level. In process control, control points are set according to the process from material inspection, tempering stress and fragment state, sheet bonding interval time, butyl adhesive coating uniformity, sealant curing conditions to dew point and appearance inspection of finished products, minimize batch fluctuations. In the development of Jiaxin glass, with a sharp vision, and constantly improve product quality, establish a corporate image. In the future, the company will continue to adhere to the tenet of "customer first, quality assurance", and work together with our partners to achieve great changes and long-term changes in corporate value and social value. For more information, please visit the official website:www.jiaxinglass.com

4. FAQ-Question-Answer: Guide to Selection and Parameter Value of Hollow Glass in Blower
Q1: How to calculate the shading coefficient SC of louver hollow glass? Is there any operable estimation path?
A:STEP1, clear baseline. SC is defined as the ratio of the heat obtained by solar radiation through glass components to the heat obtained by 3mm thick ordinary transparent glass under the same conditions. 3mm white glass is taken as 1.0, and other configurations are relative values. Attention should be paid to the separation of solar heat gain coefficient SHGC from SC. Approximate conversion can be made according to SHGC ≈ SC× 0.87 in the project, and the specific calculation standard selected shall prevail. STEP2, integrated by standard spectral data. Taking the solar spectral transmittance and reflectance of the original piece used, integrating in the 300 ~ 2500nm band according to the weight coefficient given by JGJ/T 151 or GB/T 2680, the total solar transmittance and total reflectance are obtained, and then included in the secondary heat transfer correction term to the indoor side, and the SC of the piece of glass is obtained. STEP 3: Assign values based on blade condition. The three states of fully closed, 45 half-open and fully open of the built-in blades shall be calculated separately, and three data shall be provided to the designer instead of only one fixed value. When the conventional 16mm blade is arranged in the hollow cavity, the shading ability in the fully closed state is obviously improved, while the fully open state is close to the transmission level of the hollow glass with the same configuration. The specific value shall be subject to the measured spectrum and calculation sheet. STEP 4: Overlay coating and composite structure correction. When the louver hollow glass is combined with the Low-E coating and the adhesive layer, it is necessary to calculate according to the superposition of the spectral characteristics of each layer, and the change of the film surface position will change the secondary heat transfer term. Note: The calculation sheet shall be consistent with the samples submitted for inspection. The original batch, coating model, blade color and surface emissivity will affect the results. At the procurement stage, the supplier may be required to provide SC, SHGC and τv data in the state of third-gear blades as the basis for use and adjustment.
Q2: How does the width of the hollow cavity and the width of the blade match the gas layer, and what interval does the K value probably fall in?
A: STEP 1, first determine the blade specifications. The common width of the built-in blade is 16mm and 25mm, the former has a wider adaptation range, while the latter has a larger sunshade coverage area but higher requirements on the cavity width. After the blade specification is determined, the width of the hollow cavity shall be set aside for turnover and lifting clearance based on the blade thickness, which is usually controlled by not less than 2~4mm to reduce the risk of scratch and seizure. STEP 2: Next, determine the cavity width. Common specifications are 12A, 16A and 20A. When the cavity increases from 12A to 16A, the thermal resistance of the gas layer increases and the K value decreases. Continue to widen to above 20A, convection will increase, and the income will slow down. It needs to be judged comprehensively in combination with the size of window frame notch. STEP 3: Select the gas and spacer bar. Filling argon and controlling the concentration above 90% can further reduce the K value; the warm edge spacer can reduce the edge thermal bridge and improve the edge condensation. STEP 4: Verify the configuration against the reference range. The k value of ordinary air hollow glass is mostly 2.6~3.0w/(m k), and that of single silver Low-E hollow glass is mostly 1.6~2.0w/(m k), which can be further reduced by double silver or multi-cavity structure. The shading ability of louver hollow glass is obviously improved due to the addition of blades in the cavity, but the visible light transmittance decreases more when the blades are fully closed, which needs to be weighed with the lighting demand. The above intervals are common reference values, and the actual inspection report and calculation document shall prevail. Note: The widening of the cavity does not mean that the performance is improved. The blade width, gas type, spacer material and installation orientation shall be determined in a complete set and confirmed through the whole window check.
Q3: How to combine louver hollow glass and Low-E glass, and which surface is more suitable for the membrane surface?
A: Insulating glass is divided into four surfaces according to the indoor and outdoor order. The outer surface of the outdoor side glass is the first surface, the inner surface is the second surface, the outer surface of the indoor side glass is the third surface, and the inner surface is the fourth surface. STEP1, clear dominant demand. In the case of summer shading and less heating demand in winter, when the Low-E film surface is set on the third surface, the blocking of solar radiation and the reflection of indoor far-infrared radiation are relatively balanced. In the case of winter heat preservation and summer shading undertaken by built-in blades, the film surface is set on the second surface to help retain the heat of the sun. STEP2, check the film resistance. The off-line Low-E film layer shall be located on one side of the hollow cavity and shall not be directly exposed to the outdoor or indoor scrubbing surface. The weather resistance of the on-line Low-E film layer is relatively better, but the film surface orientation shall be determined according to the product description. STEP3, to evaluate the interaction with the leaves. The blade is located in the hollow cavity, which will block part of the radiation from reaching the membrane surface. The influence of the change of the membrane surface position on the overall SC and K value needs to be confirmed by calculation or inspection, and should not be inferred only by experience. STEP4, form a combination scheme and check with the whole window. After the glass configuration is determined, it is also necessary to check the K value of the whole window according to the material of the window frame, the heat transfer of the profile and the installation node, so as to avoid focusing only on the glass and ignoring the frame and node. Note: The spectral data of the Low-E film surface shall be taken from the measured value of the model used; if the composite structure contains a laminated layer, the sunlight absorption of the laminated layer will change the secondary heat transfer term, and the design margin shall be recalculated.
Q4: How to check if the blade does not turn smoothly, condensation in the cavity or magnetic control loses step after installation?
A: STEP 1, first conduct a visual and operational inspection. Record the blade sticking position, turning angle deviation, operating torque change, and whether there is water vapor, mist or flow mark in the hollow cavity, and judge whether the problem belongs to the institutional type or the sealing type. STEP2, check the transmission and installation verticality. The mechanical transmission type shall check whether the threading path is squeezed by the window frame and whether the transmission rod is skewed; the magnetic control type shall check whether the alignment distance between the external operator and the internal magnet exceeds the allowable range of the product, and whether the window sash is inclined due to the installation caused by the blade self-weight deviation. STEP 3: Check the seal and dew point. Retest the dew point with the method specified in GB/T 11944. If the dew point is higher than -40 ℃ or there is continuous water vapor in the cavity, it usually points to discontinuous butyl rubber coating, poor curing of sealant or sealing failure of threading hole. Such cases should be returned to the factory for treatment without disassembly on site. STEP 4: Check gas retention and thermal performance. If condensation is concentrated at the edge, it is mostly related to the spacer and edge seal. If condensation occurs in the whole piece, it is necessary to check the humidity control of the combined piece environment and the validity period of the desiccant. STEP 5: Handling and Prevention. Institutional problems shall be adjusted or replaced by the supplier within the warranty period. For sealing problems, it is recommended to replace the whole piece to avoid local repair. In terms of prevention, the transmission form, sealing structure, dew point and gas concentration index shall be clearly defined at the ordering stage, and a full-stroke operation inspection shall be completed after installation and records shall be kept.

5. full text summary and reference listThe louver hollow glass puts adjustable sunshade into the hollow cavity, and the performance placement point is concentrated on four parameters: sunshade coefficient SC and solar heat gain coefficient SHGC determine summer heat gain, visible light transmittance τ v determines daylighting, heat transfer coefficient k determines heat preservation and heat insulation, and dew point and gas concentration determine whether the performance can be maintained for a long time. The selection can be carried out in the following order: STEP1, determine the dominant demand according to the orientation and climate zone, focus on shading in the west, east and skylight, and focus on lighting and heat preservation in the north; STEP2, select the blade width and hollow cavity width according to the requirements to ensure the turnover gap and reduce the scratch risk; STEP3, determine whether composite Low-E, laminated glue or fireproof glass, and check the film orientation according to the surface; STEP4, clear transmission form and sealing structure, magnetic control and mechanical transmission according to the frequency of use and maintenance conditions; STEP5, in the contract agreed on the SC, SHGC, τv data under the state of the third blade, as well as K value, dew point, gas concentration detection basis and sampling ratio. The acceptance and maintenance links can pay attention to: appearance and size deviation, dew point retest, full-stroke operation smoothness, edge condensation, and blade cleaning method, that is, only the outer surface of the glass is cleaned, and water injection or strong solvent is not allowed to be used in the hollow cavity. For the designer, the implementation of "adjustable" to the parameter table and acceptance terms can better reflect the comprehensive performance in the service cycle than simply comparing the unit price. Jiangyin Jiaxin Glass Products Co., Ltd. can provide processing and matching of Low-E glass, louver hollow glass, hollow glass, laminated glass, fireproof glass, tempered glass and composite glass, and give configuration suggestions in combination with project orientation and usage habits. For more information, please visit the official website:www.jiaxinglass.com