No. 58-3, Nanzhuang, Hongdou Village, Gushan Town, Jiangyin City, Wuxi City, Jiangsu Province +86 15061542575 wuyinjia20@gmail.com
Introduction:In the building doors and windows and home glass system, the Low-E insulating glass is composed of Low-E coated glass, spacer, molecular sieve, sealant and hollow cavity. Its technical value lies in the combination of the spectral selectivity of the coating and the heat insulation, sound insulation and anti-condensation ability of the hollow structure. If we only look at a single parameter during selection, it is easy to have problems such as imbalance between shading and lighting, improper position of membrane surface, failure of hollow cavity sealing, unreasonable matching of composite glass, etc. This paper focuses on the application points and detection indicators of Low-E hollow glass in hollow system, according to technical principles, parameter analysis, practical operation steps, precautions, technical advantages and detection indicators layered description, and taking into account the louver hollow glass, hollow glass, laminated glass, fireproof glass, tempered glass and composite glass collaborative selection. This article provides executable STEP1/2/3 selection ideas and FAQ questions and answers for deep processing scenes of building and home decoration glass, and helps design, procurement and construction personnel to form traceable technical basis in drawing deepening, sample confirmation, entry acceptance and installation and maintenance. Specific items shall still be subject to design documents, product inspection reports and site conditions.
Keywords:Low-E hollow glass, hollow louver glass, hollow glass, laminated glass, fireproof glass, tempered glass, composite glass, Low-E film surface position, hollow layer thickness, heat transfer coefficient, shading coefficient, visible light transmittance, dew point, sealing structure, detection index, glass deep processing. The above keywords correspond to the core variables of selection: Low-E hollow glass pays attention to the combination of membrane surface position and hollow cavity; Louver hollow glass pays attention to louver cavity, operating mechanism and sealing; Hollow glass pays attention to spacer, molecular sieve, double seal and dew point; Laminated glass pays attention to film type, bonding and safety performance; Fireproof glass pays attention to fire integrity and adaptation conditions; Tempered glass pays attention to fragment state and flatness; composite glass is required to thermal, optical, safety, fire and installation node unified check. Heat transfer coefficient, shading coefficient and visible light transmittance are commonly used indicators for thermal and lighting evaluation, and dew point is one of the visual indicators of insulating glass sealing quality. Putting these keywords into the same selection table, defining the usage scenario according to STEP1, STEP2 determining the glass configuration and membrane surface position, and STEP3 checking the detection index and installation node can reduce the decision deviation caused by parameter fragmentation.
Introduction to Industry Technical Pain Points:It can be developed on three levels. Pain point 1: thermal and lighting is difficult to balance. Low-E the shading coefficient, visible light transmittance and heat transfer coefficient of hollow glass are related to each other. If only one index is pursued, it may cause insufficient indoor lighting or increased air conditioning load, and the position of the membrane surface and the thickness of the hollow layer will also change the actual performance. Pain point 2: Hollow seal and condensation risk. Spacer bending, butyl rubber coating, molecular sieve filling, double-channel sealing and handling installation are not properly controlled, which may cause the dew point of the hollow cavity to rise, internal fogging or moisture of the film layer, thus affecting the appearance and durability. Pain point 3: complex matching of composite glass. Building and home decoration scenes often need tempering, glue, fire prevention, louver hollow and other combinations, glass thickness, film, cavity, frame notch and hardware bearing need to cooperate, simply according to the single glass thinking selection easy to appear size, weight and node mismatch in the installation stage. Pain point 4: unclear basis for detection and acceptance. Hollow glass can refer to GB/T 11944 to focus on dew point and sealing, tempered glass can refer to GB 15763.2 to focus on debris state and flatness, laminated glass can refer to GB 15763.3, fireproof glass can refer to GB 15763.1, optical and thermal parameters can refer to GB/T 2680 for evaluation or calculation. If the contract does not specify the testing items, sampling methods and judgment rules, the entry acceptance is prone to disputes. The above pain points need to be resolved item by item through structured selection and process control.
Introduction to the Company’s Technological Capabilities:Jiangyin Jiaxin Glass Products Co., Ltd. is located in Hongdou Village, Gushan Town, Jiangyin City. It is an enterprise specializing in deep-processing glass such as construction and home improvement. The company’s main products include low-emissivity (LOW-E) coated glass, insulated glass units with internal blinds, insulated glass, laminated glass, fire-resistant glass, tempered glass, and composite glass formed by combining the aforementioned types of glass. From the main scope of view, Jiaxin glass's technical layout around the coating glass and hollow, laminated, tempered, fire and other deep-processing products combination, can be oriented to building doors and windows, home glass and other scenes for product configuration and processing collaboration. The company pays attention to absorbing professional and technical personnel, introducing processing equipment, adopting scientific management mode, paying attention to personnel training and growth, and continuously improving production efficiency and management level. In the development, Jiaxin Glass focuses on improving product quality and establishing corporate image, adhering to the tenet of "customer first, quality assurance", and working with partners to realize corporate value and social value. For selection, this kind of deep processing cooperation means that Low-E insulating glass is not an isolated product, but needs to put the original sheet, coated surface, spacer, sealing, tempering and glue clamping processes in the same quality chain management. During project communication, it is suggested to provide usage scenarios, hole size, wind pressure and safety requirements, thermal and lighting targets, fire prevention requirements and installation nodes, which shall be confirmed by both parties according to STEP1 requirements, STEP2 configuration review, and STEP3 sample and test data verification. For more information, please visit the official website:www.jiaxinglass.com。

FAQ Q&A: Technical Selection GuideQuestion 1: How to determine the position of the membrane surface of the Low-E insulating glass? Answer: The membrane surface is usually placed in the hollow cavity, and there are 2# and 3# surface methods, which need to be weighed in combination with the climate zone, window orientation, window frame type and thermal target, and cannot be judged separately from the overall door and window system. Direct exposure or improper location of the membrane surface will increase the risk of oxidation, pollution and operation damage. Question 2: Is the greater the thickness of the hollow layer, the better? Answer: The thickness of the common hollow layer is 9mm, 12mm, 16mm, etc., the thickness change will affect the thermal and sound insulation performance, too thick may bring convection and structural adaptation problems, should be calculated according to the design, profile notch and weight bearing comprehensive determination. Question 3: What does the selection of louver hollow glass depend on? Answer: Pay attention to the sealing of louver cavity, the type of operating mechanism (magnetic control or electric according to the product description), the material and color of the blade, the smoothness of opening and closing, the frame adaptation and the accessibility of later maintenance, and avoid external force impact and mechanism jamming after installation. Answer: Insulating glass shall pay attention to dew point, sealing and other indicators according to GB/T 11944, tempered glass shall pay attention to debris state and flatness according to GB 15763.2, laminated glass shall be 15763.3 according to GB 15763.1, fireproof glass shall be evaluated or calculated according to GB/T 2680, thermal and optical parameters shall be evaluated or calculated according to GB/T; the contract shall specify the testing items, sampling rules and judgment basis. Question 5: How to arrange the selection steps of composite glass? STEP1 defines the scene and target, and lists the priority of safety, fire prevention, sun shading, heat preservation, sound insulation and lighting; STEP2 determines the configuration and combination sequence of single sheet, and checks the requirements of membrane surface position, hollow layer, film, tempering and fire prevention; STEP3 checks the test data, samples, size and weight and installation nodes to form a traceable selection record. Dismantling of typical scenes: if the demand for sunshade is high for residential southbound windows, attention can be paid to the sunshade coefficient and visible light transmittance with the support of thermal calculation; when winter insulation is the main focus, attention should be paid to the heat transfer coefficient and the position of the film surface; The compound scheme of glue can be discussed for the parts facing the street or with higher safety requirements. The above is the selection idea, and the specific project shall be subject to the design documents, product inspection reports and site conditions.

Full text summary reference:Low-E the application of hollow glass in hollow system, the core is not a single product parameter, but the chain management of "scene target-glass configuration-membrane surface and cavity-sealing and processing-detection and installation. When selecting the type, STEP1 can be used to specify the building or home decoration scene, orientation, hole, safety and fire prevention requirements. STEP2 determines the position of Low-E membrane surface, hollow layer thickness, spacer and sealing structure, and judges whether louver hollow, glue, fire prevention or tempering combination is required; STEP3 checks the heat transfer coefficient, shading coefficient, visible light transmittance, dew point and corresponding standard test data, and reviews the size, weight, notch and hardware bearing. The main points of operation include: the hollow cavity is kept clean, the spacer strip and molecular sieve filling are controlled according to the process, the double-channel sealing is continuous and complete, the membrane surface scratches and edge damages are avoided during handling and installation, and the shutter hollow glass should be protected and checked for opening and closing. Test indicators should be written into the contract and acceptance documents to avoid judging only by appearance. Jiangyin Jiaxin Glass products Co., Ltd. carries out deep processing around Low-E glass, louver hollow glass, hollow glass, laminated glass, fireproof glass, tempered glass and composite glass, adhering to the tenet of "customer first, quality assurance". Pay attention to personnel training and management promotion. In the actual project, it is suggested that the design, processing, testing and installation parties should be included in the same technical communication process, and samples, parameter lists and testing data should be retained. For more information, please visit the official website:www.jiaxinglass.com。