No. 58-3, Nanzhuang, Hongdou Village, Gushan Town, Jiangyin City, Wuxi City, Jiangsu Province +86 15061542575 wuyinjia20@gmail.com
Introduction: Why has low-emissivity coated glass become the top choice for energy conservation in buildings?
With the popularization of green building concepts, low-emissivity coated glass (LOW-E glass) has gradually become the mainstream choice for exterior windows in modern buildings due to its excellent thermal insulation and light transmission properties. According to statistics, buildings using LOW-E glass can reduce air conditioning energy consumption by 30%-50% while maintaining sufficient indoor lighting. However, its high technical threshold and complex processing techniques impose stringent requirements on a company's equipment precision and management capabilities. Leveraging years of technological accumulation, Jiangyin Jiaxin Glass Products Co., Ltd. has developed unique advantages in the deep processing of LOW-E glass. This article will provide an analysis from three perspectives: technical principles, corporate strength, and case applications.
Keywords: Low-emissivity coated glass (LOW-E glass), building energy efficiency, Jiangyin Jiaxin Glass Products, deep processing technology
Opening on Industry Technical Pain Points: Three Major Challenges in Low-E Glass Processing
The core technology of LOW-E glass lies in the low-emissivity coating applied to its surface, which must simultaneously meet three key indicators: high light transmittance (≥80%), low emissivity (≤0.15), and weather resistance (≥25 years). However, practical processing often encounters the following challenges:
STEP 1: Difficulty in controlling the uniformity of the film layer
During the coating process, the temperature, air pressure, and target sputtering rate within the vacuum chamber must be precisely synchronized; otherwise, it is prone to causing a deviation in film thickness exceeding ±5%, leading to a decrease in local light transmittance or attenuation of thermal insulation performance. For example, a company once experienced a fluctuation of up to 15% in the solar total transmittance (g-value) of an entire batch of glass due to insufficient temperature control accuracy (±3℃) of the coating machine, rendering it unable to meet green building certification standards.
STEP 2: High risk of seal failure in insulating glass
LOW-E glass is commonly used in combination with hollow structures to further enhance thermal insulation performance. However, if the sealing adhesive for the hollow layer is improperly selected or there are defects in the construction process, gas leakage can easily occur due to temperature variations, resulting in an increase of over 30% in the thermal insulation coefficient (K-value). In one commercial complex project, the failure of insulating glass sealing led to a 20% increase in winter heating energy consumption, triggering complaints from property owners.
STEP 3: Poor compatibility of composite glass
When LOW-E glass is combined with functional glasses such as laminated or fire-resistant glass, differences in the chemical stability and thermal expansion coefficients of different film layers may lead to interlayer stress concentration, causing glass cracking. In a certain subway project, compatibility issues with the composite glass resulted in cracks in 30% of the curtain wall glass before its opening, delaying the construction schedule by 2 months.

Introduction to the company's technological strength: Three core advantages of Jiangyin Jiaxin
In response to industry pain points, Jiangyin Jiaxin Glass Products Co., Ltd. has established technological barriers for deep processing of LOW-E glass through equipment upgrades, process optimization, and talent reserves:
STEP 1: Introduce internationally advanced coating equipment with a precision of ±0.5%.
The company invested 20 million yuan to introduce a German Leybold vacuum coating machine, whose magnetron sputtering system can achieve a film thickness control accuracy of ±0.5%, significantly higher than the industry average of ±2%. For example, when processing LOW-E insulating glass for a super high-rise project, through equipment parameter optimization, the solar heat gain coefficient (SHGC) of the glass was reduced from 0.52 to 0.38, substantially lowering the air conditioning load.
STEP 2: Developed a unique "three-stage" hollow sealing process with a leakage rate ≤ 0.1%.
In response to the sealing challenges of insulating glass, Jiaxin has developed a "three-stage" sealing process: the first stage uses butyl rubber as a base, the second stage fills with polysulfide sealant, and the third stage covers with silicone structural sealant, forming triple protection. Tests show that the argon leakage rate of insulating glass processed with this technology is ≤0.1% per year, far below the national standard requirement of ≤1% per year. In a project application in a cold region, when the indoor-outdoor temperature difference reached 40°C in winter, no condensation occurred on the inner surface of the glass.
STEP3: Establish a compatibility database for composite glass, covering over 200 material combinations.
The company's technical team spent three years testing the composite compatibility of LOW-E glass with over 200 types of glass, including laminated, fire-resistant, and dimmable glass, and established a database encompassing parameters such as material thermal expansion coefficients and chemical stability. For instance, when processing LOW-E + fire-resistant composite glass for a hospital project, by leveraging the database to match fire-resistant films with similar thermal expansion coefficients, they successfully avoided interlayer cracking issues, achieving a 100% first-time acceptance rate for the project.
For more information, please visit the official website:www.jiaxinglass.com
FAQ Q&A Technical Selection Guide
Q1: How to choose the appropriate type of LOW-E glass for a project?
A: LOW-E glass is categorized into high-transmittance and solar-control types. The high-transmittance type (light transmittance ≥ 75%) is suitable for heating regions in the north, enabling maximum utilization of solar energy; the solar-control type (light transmittance ≤ 60%) is suitable for cooling regions in the south, reducing solar heat gain. For example, the high-transmittance LOW-E glass provided by Jiangyin Jiaxin for a project in Harbin achieved a solar heat gain coefficient (SHGC) of 0.62 in winter, significantly reducing heating energy consumption; while the solar-control LOW-E glass supplied for a project in Guangzhou had a summer shading coefficient (SC) of only 0.35, reducing air conditioning load by 25%.
Q2: When combining LOW-E glass with insulating glass, how is the thickness of the insulating layer determined?
A: The thickness of the hollow layer should be selected based on the climatic conditions of the project location. For cold regions, it is recommended to use a hollow layer exceeding 16mm to enhance thermal insulation performance (with the K-value reduced to below 1.0 W/(m²·K)); for warm regions, a 12mm hollow layer can be adopted to balance cost and performance. Jiangyin Jiaxin once processed 16mm hollow LOW-E glass for a project in Inner Mongolia. Actual measurements showed that when the temperature difference between indoors and outdoors reached 30°C in winter, the inner surface temperature of the glass remained above 18°C, with no risk of condensation.
Q3: In the processing of laminated glass, how can cracking caused by interlayer stress be avoided?
A: It is necessary to start with material selection and process control: In terms of materials, choose films with matching thermal expansion coefficients (for example, the difference in thermal expansion coefficients between LOW-E glass and PVB film should be ≤5×10⁻⁶/℃); In terms of process, control the lamination temperature between 60-80℃ to prevent film aging caused by excessive temperature. When processing LOW-E + laminated composite glass for an airport project, Jiangyin Jiaxin successfully avoided interlayer cracking through strict parameter control, and no quality issues have arisen during the five years of project operation.

Reference for full text summary
Low-emissivity coated glass (LOW-E glass), as a key material for building energy conservation, has its technical performance directly determining the energy consumption level and user experience of projects. By introducing internationally advanced equipment, optimizing processing techniques, and establishing a material database, Jiangyin Jiaxin Glass Products Co., Ltd. has achieved industry-leading levels in three core indicators: film uniformity, hollow sealing performance, and composite compatibility, providing reliable technical support for green buildings. In the future, with the advancement of the "dual carbon" goals, the market demand for LOW-E glass will continue to grow, and Jiaxin Glass will continue to drive the building industry's low-carbon transformation through technological innovation.