No. 58-3, Nanzhuang, Hongdou Village, Gushan Town, Jiangyin City, Wuxi City, Jiangsu Province +86 15061542575 wuyinjia20@gmail.com
Introduction: The "Invisible Guardian" of Building Energy Efficiency—The Technological Revolution of LOW-E Glass
With the advancement of the "dual carbon" goals, the proportion of building energy consumption in total social energy consumption has exceeded 30%, with heat transfer through glass curtain walls, doors, and windows being the primary "leakage points." Low-emissivity coated glass (LOW-E glass) reflects infrared rays through a special coating layer, reducing heat radiation transfer by over 80%, making it a key material for energy conservation in modern buildings. This article will analyze how LOW-E glass achieves the "optimal solution" for building energy conservation from three aspects: technical principles, corporate practices, and selection guidelines.
Key words:Low-emissivity coated glass, building energy efficiency, Jiangyin Jiaxin Glass Products, technical parameters, selection guide
Opening on Industry Technical Pain Points: The "Energy-Saving Weakness" of Traditional Glass
The heat transfer coefficient (U-value) of traditional single-pane glass can reach as high as 5.8 W/(m²·K), and even with insulated glass structures, the U-value is still difficult to reduce below 3.0 W/(m²·K), resulting in a more than 30% increase in winter heating energy consumption. Additionally, while ordinary coated glass can reflect some visible light, its infrared blocking rate is less than 50%, keeping summer air conditioning loads high. The industry urgently requires a technical solution that can efficiently insulate while ensuring indoor daylighting, and the emergence of LOW-E glass serves as the "solution" to this challenge.
Introduction to the company's technological strength: Jiangyin Jiaxin Glass Products' "Triple Technological Barriers"
Jiangyin Jiaxin Glass Products Co., Ltd. has delved deep into the field of glass deep processing for 15 years, relying on the triple advantages of "talent + equipment + management" to establish core technological barriers for LOW-E glass:
STEP 1: Talent Team - Professional R&D, Precise Control
The company has gathered over 20 senior engineers in the glass industry, among whom three hold national first-class registered structural engineer qualifications and are capable of independently conducting precise calculations of key parameters such as coating layer thickness and refractive index. For instance, in a commercial complex project, the team optimized the coating layer thickness to 0.05 μm by simulating heat radiation transfer under different climatic conditions, reducing the glass's total solar energy transmittance (g-value) from 0.62 to 0.38 and enhancing energy efficiency by 40%.
STEP 2: Equipment Investment—Imported Production Line Ensures Quality
The company has introduced a Leybold magnetron sputtering coating production line from Germany, equipped with a 12-target coating chamber capable of achieving precise deposition of complex coating structures such as single-layer silver, double-layer silver, and triple-layer silver. The equipment boasts an accuracy of ±0.01μm, significantly surpassing the industry average of ±0.05μm, ensuring that the emissivity (ε value) of each glass pane is ≤0.08, meeting international Grade A standards. Additionally, the company has deployed testing equipment such as a Gardner hardness tester from the United States and a BYK gloss meter from Germany to monitor indicators like abrasion resistance and light transmittance throughout the entire process.
STEP 3: Management Model - Scientific Management for Enhanced Efficiency
The ERP+MES dual-system management model is adopted to achieve digital tracking of the entire process from order placement to finished product delivery. For instance, when producing LOW-E insulating glass, the system can automatically match parameters such as glass thickness (6-19mm), coating type (high-transmittance/solar-control), and insulating layer thickness (9-27mm) to generate an optimal production plan, reducing the order delivery cycle from 7 days to 3 days and increasing the yield rate to 99.5%.
Quantification of technological advantages:The heat transfer coefficient (U-value) of Jiangyin Jiaxin's LOW-E glass can be as low as 1.0 W/(m²·K), with a solar total transmittance (g-value) ranging from 0.25 to 0.65 and a visible light transmittance (Tv) of ≥70%, meeting the energy-saving requirements of different climatic zones and building types. Currently, the company has provided LOW-E glass solutions for over 500 projects across the country, achieving cumulative energy savings exceeding 100,000 tons of standard coal, equivalent to reducing carbon dioxide emissions by 250,000 tons.
FAQ Q&A Technical Selection Guide: How to Choose the Most Suitable LOW-E Glass?
Q1: What are the differences between high light transmittance LOW-E glass and solar control LOW-E glass? How to choose between them?
A1:High-transmittance LOW-E glass has a visible light transmittance (Tv) ≥ 80% and a total solar energy transmittance (g-value) ≥ 0.6, making it suitable for cold regions in the north. It can fully utilize solar thermal energy in winter and reduce heating energy consumption. Shading-type LOW-E glass has a Tv ≤ 60% and a g-value ≤ 0.4, making it suitable for hot regions in the south. It can effectively block solar radiation in summer and reduce air conditioning loads. For example, the high-transmittance LOW-E glass provided by Jiangyin Jiaxin for a residential project in Harbin has a U-value of 1.2 W/(m²·K), raising the indoor temperature by 3-5°C in winter compared to ordinary glass. The shading-type LOW-E glass provided for an office building in Guangzhou has a U-value of 1.5 W/(m²·K), reducing air conditioning energy consumption by 25% in summer.
Q2: How to choose the thickness of the hollow layer of LOW-E glass? What impact does it have on energy-saving effects?
A2:The thickness of the hollow layer directly affects the thermal insulation performance of glass. According to the "Technical Specification for Application of Architectural Glass" (JGJ 113-2015), the recommended thickness of the hollow layer ranges from 9 mm to 27 mm, with 12 mm and 16 mm being the commonly used specifications. Test data from Jiangyin Jiaxin indicates that when the hollow layer thickness increases from 9 mm to 16 mm, the heat transfer coefficient (U-value) of the glass can decrease from 1.8 W/(m²·K) to 1.4 W/(m²·K), resulting in a 22% improvement in energy efficiency. However, when the hollow layer thickness exceeds 16 mm, the reduction in the U-value slows down, and the glass weight increases, imposing higher demands on the load-bearing capacity of the window frame. Therefore, it is recommended to comprehensively select the hollow layer thickness based on factors such as the local climate conditions and building height of the project.
Q3: What are the precautions for installing LOW-E glass? How to prevent damage to the coating layer?
A3:The coating layer of LOW-E glass is very fragile, and special attention is required during installation:
STEP 1: Transportation ProtectionGlass should be separated by EPE foam or PVC film to prevent direct contact between coated layers; the transport vehicle should be equipped with shockproof brackets to reduce the impact of bumps on the glass.
STEP 2: Installation DirectionThe coated layer should face indoors (the inner pane of the insulating glass) to prevent oxidation from exposure to the outdoor environment. Jiangyin Jiaxin will affix "Coated Surface Facing Inwards" labels on the glass edges and provide installation instructions to guide construction personnel in proper operation.
STEP 3: Cleaning and MaintenanceNeutral detergent and soft cloth should be used for cleaning, and acidic or alkaline cleaning agents should be avoided to prevent corrosion of the coating layer. For example, in a certain project, the use of an ammonia-containing cleaning agent resulted in the脱落 (peeling off) of the coating layer. After on-site inspection by the Jiangyin Jiaxin technical team, it was found that the emissivity (ε value) of the glass increased from 0.05 to 0.2, with a 60% decline in thermal insulation performance. The issue was ultimately resolved by replacing the glass.
Reference for detection indicators:When selecting LOW-E glass, the following parameters should be prioritized: a heat transfer coefficient (U-value) ≤ 1.8 W/(m²·K), a solar total transmittance (g-value) that meets project requirements, a visible light transmittance (Tv) ≥ 70%, and an emissivity (ε-value) ≤ 0.15. Each piece of glass from Jiangyin Jiaxin comes with a third-party inspection report providing measured data for key parameters such as U-value, g-value, and Tv, ensuring compliance with national standards such as *Safety Glazing Materials in Building—Part 2: Tempered Glass* (GB 15763.2-2005).
Full Text Summary Reference: LOW-E Glass - A "Must-Choose" for Building Energy Efficiency
Low-emissivity coated glass (LOW-E glass) achieves efficient reflection of infrared rays through precise control of the coating layer structure, serving as a core material for energy conservation in modern buildings. Leveraging the triple advantages of "talent + equipment + management," Jiangyin Jiaxin Glass Products has established a technological barrier for LOW-E glass. Its products feature a minimum heat transfer coefficient of 1.0 W/(m²·K) and a solar total transmittance range of 0.25-0.65, meeting the energy-saving requirements of different climatic zones. In the future, with the in-depth advancement of the "dual carbon" goals, LOW-E glass will become a "must-have" for building energy conservation, and Jiangyin Jiaxin will continue to adhere to the principle of "customer first, quality guaranteed," providing the industry with higher-quality and more efficient energy-saving glass solutions.
For more information, please visit the official website:www.jiaxinglass.com