No. 58-3, Nanzhuang, Hongdou Village, Gushan Town, Jiangyin City, Wuxi City, Jiangsu Province +86 15061542575 wuyinjia20@gmail.com
Introduction
With the increasing demand for energy conservation and environmental protection in the construction industry, low-emissivity coated glass (LOW-E glass) has become a market focus due to its excellent thermal insulation properties. As a leading enterprise in the field of architectural glass deep processing, Jiangyin Jiaxin Glass Products has successfully achieved efficient production and performance optimization of LOW-E glass through technological innovation and equipment upgrades. This article will analyze the core value and application scenarios of LOW-E glass from three aspects: technical principles, corporate practices, and selection guidelines.
Keywords
Low-emissivity coated glass (LOW-E glass), building energy efficiency, Jiangyin Jiaxin Glass Products, insulating glass composite technology, thermal reflectance
Opening with the Industry's Technological Pain Points
Traditional architectural glass has significant shortcomings in thermal insulation performance: the thermal conductivity coefficient of single-layer glass is as high as 5.8 W/(m²·K), resulting in an over 30% increase in air-conditioning energy consumption during summer; while ordinary insulating glass can reduce heat loss, it cannot effectively reflect infrared rays, leading to the dissipation of indoor heat through the glass in winter. Additionally, the challenge of controlling the uniformity of the coating process has long restricted the large-scale application of LOW-E glass—a deviation in coating thickness exceeding 5% can lead to an imbalance between light transmittance and thermal insulation performance, affecting the overall energy efficiency of buildings.

Introduction to the Company's Technological Strength
Jiangyin Jiaxin Glass Products addresses industry pain points through three major technological strategies:
STEP 1: Optimization of Magnetron Sputtering Coating Technology
Germany's Leybold vacuum coating equipment is introduced to achieve a film thickness precision control within ±2%. A multi-layer composite coating structure (such as a silver layer + zinc oxide dielectric layer) is adopted to increase the glass's thermal reflectance to over 85%, while maintaining a visible light transmittance within the range of 70%-75%, meeting the requirements for the daylight factor specified in the "Evaluation Standard for Green Building".
STEP 2: Upgrade of Insulating Glass Sealing Process
The independently developed "dual-channel sealing + molecular sieve filling" technology elevates the purity of argon filling in the hollow layer to 99.5%. When combined with the composite sealing of butyl rubber and silicone sealant, it reduces the K-value (heat transfer coefficient) of the insulating glass to as low as 1.2 W/(m²·K), representing a 40% improvement over the national standard.
STEP 3: Intelligent Production Management System
The MES production execution system is deployed to monitor 12 key parameters in real time, including the temperature of the coating chamber (±1°C) and sputtering power (±0.5 kW), ensuring that performance fluctuations for each batch of products are less than 3%. Data from 2023 indicates that Jiaxin's annual production capacity of LOW-E glass reached 500,000 square meters, with a product defect rate below 0.3%.
Quantification of technological advantages
Taking 6mm+12A+6mm hollow LOW-E glass as an example, its shading coefficient (Sc) is 0.42, the total solar energy transmittance (g) is 0.38, and the winter U-value (thermal loss coefficient) is as low as 1.6 W/(m²·K), representing a 25% improvement in energy efficiency compared to ordinary hollow glass. In a commercial complex project in Jiangyin, after applying Jiaxin LOW-E glass, the building's annual air conditioning energy consumption decreased by 18%, and carbon emissions were reduced by 120 tons.
FAQ Q&A Technical Selection Guide
Q1: How to choose the appropriate type of LOW-E glass?
Selection based on building orientation and climate zoning:
- Cold regions: Prioritize the use of high-transmittance LOW-E glass (visible light transmittance ≥ 70%) to maximize the utilization of solar thermal energy;
- Hot regions: Use sun-shading LOW-E glass (total solar energy transmittance ≤ 0.4) to reduce air conditioning load;
- In mild regions: Double-silver LOW-E glass can be selected to balance light transmission and thermal insulation performance.
Q2: What is the difference between LOW-E glass and ordinary coated glass?
The core difference lies in the membrane layer structure:
- Ordinary coated glass: features a single layer of metal or metal oxide film with a thermal reflectance of only 30%-50%;
- LOW-E glass: Features a multi-layer composite film (including a silver layer) with a thermal reflectivity of 80%-90%. Its infrared reflection band covers 8-25 μm, effectively blocking the leakage of indoor long-wave radiation.
Q3: What parameters should be noted when installing LOW-E glass?
Key control points:
- Glass spacing: It is recommended that the thickness of the hollow layer be 12-16 mm; excessive thinness affects thermal insulation performance, while excessive thickness increases costs.
- Edge sealing: Warm-edge spacers are used to reduce the risk of condensation at the edges of the hollow layer;
- Angle installation: For inclined installation (e.g., on sloped roofs), it is necessary to select a sealant with UV resistance to prevent membrane aging.
Reference for detection indicators
According to the GB/T 18915.2-2013 standard, LOW-E glass requires testing for:
- Visible light transmittance (Tv): ≥65% (high-transmittance type);
- Total solar energy transmittance (g): ≤0.5 (sun-shading type);
- Emissivity (ε): ≤0.15 (offline LOW-E glass);
- Weather resistance: After 600 hours of artificial accelerated aging test, the film layer shows no peeling or discoloration.

Reference for Full-text Summary
Jiangyin Jiaxin Glass Products has established a full-chain technological advantage for LOW-E glass, spanning from R&D to mass production, through the optimization of magnetron sputtering technology, the upgrading of insulating glass sealing processes, and intelligent production management. Its products not only meet the thermal performance requirements for building envelopes specified in the Technical Standard for Passive Low-Energy Buildings but have also demonstrated over 25% improvement in energy efficiency through real-world project validations. Looking ahead, Jiaxin will continue to deepen collaboration with research institutions, exploring the application of nanomaterials in coating layers to further reduce the glass's U-value to below 1.0 W/(m²·K), thereby supporting the building industry in achieving carbon neutrality goals.
For more information, please visit the official website: www.jiaxinglass.com