Introduction:Driven by the "dual carbon" goals, the demand for energy-saving materials in the construction industry has become increasingly urgent. Low-emissivity coated glass (LOW-E glass) has become the preferred material for modern building curtain walls and door and window systems due to its excellent thermal reflection properties and light transmittance. This article will systematically analyze how LOW-E glass achieves the integration of efficient energy conservation and architectural aesthetics from three aspects: technical principles, corporate practices, and selection guidelines, and will share the technological layout and implementation cases of Jiangyin Jiaxin Glass Products.
Key words:Low-emissivity coated glass (LOW-E glass), building energy efficiency, Jiangyin Jiaxin Glass Products, technology selection, composite glass
Introduction to the Pain Points in Industry Technology:Traditional architectural glass has two core pain points: first, its high thermal conductivity coefficient leads to the loss of indoor heat in winter and the intrusion of outdoor heat in summer, increasing air conditioning energy consumption; second, its single-function design makes it difficult to balance light transmittance and heat insulation, limiting the flexibility of architectural design. For example, a commercial complex project once used ordinary insulating glass, resulting in air conditioning energy consumption accounting for 45% of the total annual energy consumption, and the issue of curtain wall reflection triggered complaints from nearby residents. LOW-E glass, by depositing multiple layers of metal oxide films on the glass surface, can selectively reflect infrared rays (thermal radiation) while maintaining visible light transmission, effectively addressing the aforementioned pain points. The key to its technology lies in the proportion of film materials and the precision of the coating process, which require strict quality inspections to ensure performance stability.
Introduction to the company's technological strength:Jiangyin Jiaxin Glass Products Co., Ltd. has been deeply engaged in the field of glass deep processing for over a decade, focusing on the research, development, and production of high-end products such as LOW-E glass and louvered insulating glass. The company has introduced a German Leybold optical coating production line, equipped with high-precision testing equipment including an online ellipsometer and a spectrophotometer, enabling a coating thickness control accuracy of ±0.5nm. This ensures that the product's thermal reflectance is ≥80% and the visible light transmittance is adjustable within the range of 30%-70%. The technical team, composed of 10 senior engineers covering fields such as materials science, optical engineering, and mechanical automation, has collectively obtained 6 utility model patents and led the formulation of the enterprise standard "Composite Process Specification for LOW-E Glass Used in Buildings." In project practice, the company adopts a full-process management and control model encompassing "design-production-installation." For instance, the LOW-E insulating glass composite solution provided for a super high-rise office building optimized the coating structure and insulating layer thickness (16mm), resulting in a 32% increase in the project's overall energy efficiency and earning the "Three-Star Green Building Label."For more information, please visit the official website: www.jiaxinglass.com

FAQ Q&A Technical Selection Guide:Q1: How to select the coating type of LOW-E glass based on building types?
STEP 1: Clarify functional requirements. In northern heating regions, high-transmittance LOW-E glass (visible light transmittance ≥ 60%) should be prioritized to fully utilize solar thermal energy; in southern cooling regions, solar-control LOW-E glass (visible light transmittance of 30%-50%) is more suitable to reduce solar heat gain.
STEP 2: Match the glass structure. Single-pane LOW-E glass should be used in conjunction with an insulating layer, with a recommended thickness of 12-16 mm for the insulating layer; filling it with argon can further enhance thermal insulation performance. For composite glass (such as LOW-E + laminated glass), the compatibility between the coating layer and the PVB interlayer should be verified to avoid the risk of delamination.
STEP 3: Verify performance parameters. Key indicators include the shading coefficient Sc (≤0.5 for the south and ≤0.7 for the north), heat transfer coefficient K value (≤1.8 W/(㎡·K)), and light-to-solar gain ratio LSG (≥1.25). For example, the 6Low-E+12Ar+6 insulating glass provided by Jiangyin Jiaxin for a hospital project has a measured K value of 1.6 W/(㎡·K) and an Sc value of 0.48, meeting the energy efficiency requirements for green buildings.
Q2: What are the key technical points to note during the installation of LOW-E glass?
STEP 1: Film layer protection. During transportation and storage, keep the glass film layer facing upwards and avoid contact with hard objects. Before installation, clean the glass surface with a neutral detergent to prevent oil stains from affecting the performance of the film layer.
STEP 2: Sealing treatment. For insulating glass, polysulfide sealant or silicone sealant should be selected, with a sealing width of ≥10 mm and a depth of ≥8 mm to ensure airtightness; for laminated glass, a 2-3 mm expansion joint should be reserved between the laminated layer and the frame to prevent cracking caused by thermal expansion and contraction.
STEP 3: Quality Inspection. After installation, an infrared thermal imager inspection shall be conducted to confirm the absence of thermal bridge defects; a lux meter shall be used to measure the uniformity of indoor daylighting, with the deviation value required to be ≤15%.

Please provide the Chinese text that you would like translated into English.As a key material for energy conservation in buildings, the technological core of LOW-E glass lies in film layer design and process control. Jiangyin Jiaxin Glass Products has established a complete technological system from research and development to implementation by introducing advanced equipment, assembling a professional team, and formulating corporate standards, providing replicable energy-saving solutions for the industry. In the future, with the advancement of "zero-carbon building" standards, LOW-E glass will be upgraded toward higher light transmittance and lower emissivity. Jiangyin Jiaxin will continue to optimize composite glass technology to facilitate the green transformation of the construction industry.For more information, please visit the official website: www.jiaxinglass.com