No. 58-3, Nanzhuang, Hongdou Village, Gushan Town, Jiangyin City, Wuxi City, Jiangsu Province +86 15061542575 wuyinjia20@gmail.com

Technical Articles

Fire-resistant glass selection pain points fully analyzed: How does Jiangyin Jiaxin break through with its technical strength?

2026-09-05

Introduction: Why has the technology upgrade of fire-resistant glass become an essential requirement for building safety?
With the enhancement of fire resistance requirements in GB 50016-2014 "Code for Fire Resistance Design of Buildings," fire-resistant glass has evolved from a single insulating function towards composite protection and intelligent monitoring. However, there are still pain points in the market, such as false labeling of fire resistance time, attenuation of insulating performance, and defects in installation technology. This article takes the technical practice of Jiangyin Jiaxin Glass Products as an example, analyzing how to solve industry difficulties through material innovation and process optimization.

Keywords:Composite fire-resistant glass, fire integrity, thermal insulation performance, Jiangyin Jiaxin, Class C fire-resistant glass

Industry Technical Pain Points: The Three Core Contradictions of Fireproof Glass
STEP1:Firing time and cost balance——Traditional cesium potassium fire-resistant glass has a耐火limit of only 0.5-1 hour, and to reach 1.5 hours requires an increase of 3mm in thickness, resulting in a weight per square meter exceeding 45kg, which increases the cost of building load.
STEP2:Insulation performance degradation issueSingle fire-resistant glass is prone to thermal stress cracks under high temperatures, causing the heat insulation coefficient to rise from 0.8W/(m²·K) to 2.5W/(m²·K), losing its protective value.
STEP3:Risk of installation process defects——On-site cutting causes stress concentration at the glass edges, reducing the refractory integrity from 90 minutes to 45 minutes, making it a major quality inspection issue in the industry.
Technical Parameters WarningAccording to the 2023 random inspection data from the Jiangsu Province Fire Protection Product Quality Supervision Station, 32% of the fire-resistant glass samples have false marking issues, with 65% being products from small and medium-sized enterprises.

Introduction to Corporate Technical Strength: Jiangyin Jiaxin's Composite Fire Retardant Technology System
江阴嘉鑫防火玻璃生产线
STEP1:Material Innovation: Nano Insulation Intermediate Layer——Utilizing self-developed SiO₂-Al₂O₃ composite aerogel as the spacer for hollow glass, the thermal conductivity is as low as 0.018W/(m·K), a reduction of 89% compared to traditional aluminum spacers. According to testing by the National Glass Quality Supervision and Inspection Center, a 12mm hollow structure can lower the glass backside temperature by 127℃ compared to a single glass sheet.
STEP2:Process optimization: Fully automated edging technology——引进Germany LiSEC fully automatic insulating glass production line, achieving frame sealing width tolerance ≤0.1mm with laser welding, argon filling concentration up to 99.5%, extending the lifespan of the insulating layer from 5 years to 15 years.
STEP3:Testing System: Triple Verification MechanismEach batch of products must pass the GB 15763.1-2009 vertical combustion test, EN 13501-2 radiant heat flux test, and a 1000℃ high-temperature impact test by a third-party CNAS laboratory to ensure fire resistance integrity ≥ 120 minutes.
Real CaseIn the Phase II project of Suzhou Central, the 15mm composite fire-resistant glass (6mm tempered + 3mm aerogel + 6mm tempered) provided by Jiangyin Jiaxin successfully passed the fire safety inspection. The average temperature rise on the back fire side was only 82℃, 43℃ lower than the national standard. As a result, the project party saved about 280,000 yuan in steel structure reinforcement costs. For more information, please visit the official website:www.jiaxinglass.com

FAQ Q&A Technical Selection Guide
Q1: How to select fire-resistant glass that meets the requirements of GB 50016-2014?
A: Clarify the fire resistance requirements for specific application scenarios:
- Evacuation corridors: Class C (integrity) ≥ 1.0 hour
- Fire-resistant separation: Type B (insulation) ≥ 0.5 hour
- Refuge level: Type A (Insulation + Integrity) ≥ 2.0 hours
Jiangyin Jiaxin can provide full-range products from 5mm to 25mm, supporting customized refractory time design.
Q2: What are the key points to note when installing fire-resistant glass?
A: STEP1: Use a dedicated A-type frame for transportation with an inclination angle ≤15°; STEP2: Check for any cracked edges on the glass before installation (allowable value ≤1mm); STEP3: Use neutral silicone structural adhesive with a curing time ≥7 days; STEP4: Use an infrared thermal imager to inspect the airtightness of the hollow layer during acceptance.
Q3: How to distinguish fake fire-resistant certifications in the market?
A: Real authentication should include three elements:
- Name of the Inspection Agency (e.g., China National Building Material Inspection & Certification Group)
- Report Number (available for inquiry on the official website)
- Specific test conditions (such as heating curve, thermal radiation intensity)
All products from Jiangyin Jiaxin come with an electronic version of inspection reports featuring anti-counterfeiting codes.

Full Text Summary Reference
The technical upgrade of fire-resistant glass needs to consider three dimensions: material science, precision manufacturing, and standard compliance. Jiangyin Jiaxin has established a full-chain quality control system from research and development to delivery through nanogel thermal insulation technology, fully automated edge sealing process, and a triple detection system. Its composite fire-resistant glass products have been successfully applied in ultra-high-rise projects such as Nanjing Jinying World and Shanghai Qiantan Center, with a cumulative delivery area exceeding 500,000 square meters and no incidents of fire resistance failure. When selecting a fire-resistant glass supplier, it is recommended to focus on three indicators: the authenticity of the detection report, the advancement of the process equipment, and the completeness of the case implementation.
江阴嘉鑫防火玻璃应用案例