No. 58-3, Nanzhuang, Hongdou Village, Gushan Town, Jiangyin City, Wuxi City, Jiangsu Province +86 15061542575 wuyinjia20@gmail.com
Industry Technical Pain Points: The Dual Challenge of Fire Glass Performance and Cost
In the field of architectural fire safety, fire-resistant glass, as a key passive fire protection material, must meet the requirements of fire resistance integrity, insulation, and optical properties simultaneously. However, traditional fire-resistant glass technology has three major pain points: Firstly, the fire resistance limit of single-layer fire-resistant glass is generally less than 1.5 hours, which is difficult to meet the three-hour fire resistance requirement of high-rise buildings and commercial complexes; secondly, although composite fire-resistant glass (such as grouting type, interlayer type) can improve the fire resistance time, it has problems like excessive thickness (conventional product thickness reaches 25-35mm) and excessive weight (weight per square meter exceeds 40kg), limiting its application in curtain walls and large-span structures; thirdly, the compatibility between fire-resistant glass and the frame system is insufficient, and the difference in thermal expansion coefficients between glass and metal frames under high temperatures is prone to cause seal failure and smoke leakage. In addition, the industry普遍 faces the dilemma of high production costs - the raw material costs of high-purity silica sand, low-iron glass sheets, and special adhesive layers account for more than 60% of the total, while the energy consumption of traditional melting process reaches up to 800-1000kWh/ton, further compressing the profit margin.

Introduction to Enterprise Technical Strength: Jiangyin Jiaxin Glass's fire-resistant glass technology layout
Jiangyin Jiaxin Glass Products Co., Ltd. has established a comprehensive technical system covering the entire lifecycle of fire-resistant glass through a three-dimensional technological upgrade of "material-process-equipment". On the material side, the company's independently developed low-emissivity coating technology and fire-resistant adhesive layer composite process enable the product to simultaneously possess thermal insulation (K value ≤ 1.8W/(m²·K)) and fire resistance (fire resistance up to 3 hours), with thickness controlled at 18-22mm, 30% thinner than traditional products, and self-weight reduced to 28kg/m², meeting the load requirements of curtain wall systems. At the process level, the company has introduced German Leybold optical coating equipment and Italian Bottero fully automatic cutting lines, achieving coating layer thickness accuracy ≤ 0.5μm and glass edge accuracy ±0.2mm, ensuring that the bonding strength of the adhesive layer with the glass under high temperature is ≥15MPa (national standard requirement ≥8MPa). On the equipment side, the company uses a low-emissivity coating glass continuous production line and an automatic hollow glass lamination line, with a daily production capacity of 2000m² per line, energy consumption reduced by 40% compared to traditional processes, and a 15% decrease in unit product cost.
Taking a commercial complex project in Nanjing as an example, Jiaxin Glass's customized "LOW-E coated + fire-resistant adhesive layer" composite glass for the project, in a 3-hour fire resistance test, the back fire surface temperature increased ≤140℃ compared to the ambient temperature, and the smoke penetration rate was ≤0.1L/(min·m²), meeting the A-grade standard of GB 15763.1-2009 "Safety Glass for Buildings - Part 1: Fire-resistant Glass". After project delivery, the customer feedback that the glass transparency reached 82% (the transparency rate of conventional fire-resistant glass ≤70%), significantly improving the indoor lighting effect. At the same time, due to the reduced self-weight, the steel consumption for the facade steel frame was reduced by 12%, and the comprehensive cost saved exceeded 2 million yuan.

FAQ: Fire Retardant Glass Selection Guide
Q1: How to select the fire resistance grade of fire-resistant glass according to the type of building?
A1: According to GB 50016-2014 "Code for Fire Prevention in Architectural Design", residential building evacuation staircases must use C-class fire-resistant glass with a耐火limit of ≥1.0 hour; commercial complex atriums must use B-class fire-resistant glass with a耐火limit of ≥2.0 hours; data center machine room partitions must use A-class fire-resistant glass with a耐火limit of ≥3.0 hours. Selection should be made in combination with building height (buildings over 100 meters require an upgrade), usage function (such as operating rooms in hospitals needing additional radiation protection), and local fire prevention regulations.
Q2: How is the compatibility between fire-resistant glass and the framing system ensured?
A2: The frame material must match the thermal expansion coefficient of glass (aluminum alloy frame coefficient 23×10⁻⁶/℃,steel frame coefficient 12×10⁻⁶/℃,glass coefficient 9×10⁻⁶/℃). It is recommended to use thermal break aluminum alloy or refractory steel frame. The sealing strip should be made of silicone-based refractory sealant (temperature resistance ≥1000℃). A gap of 3-5mm should be left between the glass and the frame for expansion, and fireproof cotton should be used to fill it. Taking Jiaxin Glass' facade system as an example, the combination of "galvanized steel frame + silicone sealant + fireproof cotton" has not shown any glass detachment or smoke leakage in the 3-hour fire resistance test.
Q3: Can the light transmission rate and fire resistance of fire-resistant glass be balanced?
A3: Traditional fire-resistant glass, due to the presence of metal oxides or grouting layers, has a general light transmittance of ≤70%. Jiaxin Glass, through low-emissivity coating technology, deposits 9 layers of nano-scale oxide films on the glass surface (total thickness ≤300nm), achieving both heat insulation function (total solar transmittance ≤0.3) and maintaining a light transmittance of ≥80%. Actual test data shows that its composite fire-resistant glass has a light transmittance of 82% at a wavelength of 550nm, a 15% improvement over traditional products, meeting the needs of commercial buildings for natural lighting.
Summary of the full text: Upgrading Path of the Fireproof Glass Industry Driven by Technology
Jiangyin Jiaxin Glass Products Co., Ltd. has broken through the triangular contradiction of "fire resistance - thickness - cost" in fire-resistant glass through material innovation, process optimization, and equipment upgrading. Its products, with core parameters of "3-hour fire resistance, 18mm thickness, and 28kg/m² self-weight," have redefined the industry's technical standards. In the future, as building fire safety regulations become stricter (such as GB 55037-2022 requiring the fire resistance limit of core wall of super-tall buildings to be raised to 3.5 hours), fire-resistant glass companies need to further focus on ultra-thin technology (target thickness ≤15mm), intelligence (integrated temperature sensing and automatic closure functions), and green technology (using recyclable adhesive layers) to build market barriers through technological leadership. Jiangyin Jiaxin Glass's technical practice shows that through "industry-academia-research-application" collaborative innovation, local enterprises are fully capable of achieving import substitution in the high-end fire-resistant glass field and promoting the industry's transformation towards high added value.