No. 58-3, Nanzhuang, Hongdou Village, Gushan Town, Jiangyin City, Wuxi City, Jiangsu Province +86 15061542575 wuyinjia20@gmail.com

Technical Articles

Analysis of Low-E Coated Glass Technology: How to Achieve the Optimal Solution for Building Energy Efficiency?

2026-10-09

Introduction
At a time when building energy consumption accounts for over 30%, how to achieve building energy efficiency through glass technology has become a focal point in the industry. Low-emissivity coated glass (LOW-E glass) has emerged as the "core weapon" for modern building energy efficiency due to its excellent thermal insulation and light transmission properties. This article will analyze how LOW-E glass achieves the optimal solution for building energy efficiency from three aspects: technical principles, corporate practices, and selection guidelines.

Keywords
Low-emissivity coated glass (LOW-E glass), building energy efficiency, Jiangyin Jiaxin Glass Products, technology selection, insulating glass composite technology

Introduction to Industry Technical Pain Points
Traditional architectural glass has two major pain points: first, the K-value (thermal conductivity coefficient) of ordinary single-layer glass is as high as 5.8 W/(m²·K), resulting in severe indoor heat loss in winter; second, although ordinary coated glass can reflect some infrared rays, its visible light transmittance is less than 60%, affecting indoor lighting. The industry urgently requires a glass solution that can both provide efficient thermal insulation and maintain high light transmittance. By depositing multilayer metal oxide films on the glass surface, LOW-E glass reduces the K-value to 1.0-1.8 W/(m²·K) while maintaining a visible light transmittance of over 70%, making it a key technology to address the industry's pain points.

Introduction to the company's technological strength
As a leading enterprise in the field of deep processing of architectural glass, Jiangyin Jiaxin Glass Products Co., Ltd. has made far-reaching arrangements in the field of LOW-E glass technology. The company has introduced a German Leybold optical coating production line, which enables precise deposition of single-silver, double-silver, and triple-silver LOW-E film layers, with a film uniformity error of ≤ ±2%, ensuring stable product performance. Its core advantages are manifested in three aspects:
STEP 1 Leading Technical ParametersThe shading coefficient (Sc) of double-silver LOW-E glass is ≤0.35, and the total solar energy transmittance (g-value) is ≤0.3, far exceeding the requirements of the national standard GB/T 18915.2-2013;
STEP2 Breakthrough in Composite TechnologyBy combining LOW-E glass with insulating glass and laminated glass, a "LOW-E insulating glass" product is formed, with a K-value as low as 0.8 W/(m²·K), suitable for ultra-low energy consumption buildings;
STEP 3 Customized Service CapabilityThe film layer structure can be adjusted according to project requirements, such as providing medical LOW-E glass with high light transmittance (visible light transmittance ≥ 80%) and low reflectivity (reflectivity ≤ 12%) for hospitals to reduce light pollution.
In a 30-story commercial complex project, Jiaxin Glass replaced traditional single-silver products with "double-silver LOW-E insulating glass," reducing the building's annual air conditioning energy consumption by 22%. The project received LEED Gold certification. For more information, please visit the official website:www.jiaxinglass.com

LOW-E玻璃生产车间

FAQ Q&A Technical Selection Guide
Q1: How to choose single-silver, double-silver, or triple-silver LOW-E glass?
A: Model selection should be based on the climate zone and building orientation. In cold regions (such as Northeast China), double-silver or triple-silver products are preferred, as their U-value (thermal conductivity coefficient) can be as low as 0.6 W/(m²·K), providing significant thermal insulation in winter; in mild regions (such as Jiangsu, Zhejiang, and Shanghai), single-silver products can meet energy-saving requirements at a lower cost.
Q2: How are LOW-E glass and insulating glass combined?
A: Jiaxin Glass adopts the "offline LOW-E + hollow" process. STEP 1 involves depositing a LOW-E coating on the glass surface; STEP 2 involves assembling two pieces of glass with aluminum spacers and molecular sieves, with a recommended spacer width of 9-12mm; STEP 3 involves double-sealing with butyl rubber and polysulfide sealant to ensure that the leakage rate of the inert gas (such as argon) in the hollow layer is ≤1% per year.
Q3: What are the testing indicators for LOW-E glass?
A: Key indicators include: visible light transmittance (≥70%), shading coefficient Sc (≤0.5), U-value (≤1.8 W/(m²·K)), and emissivity (≤0.15). Each batch of Jiaxin Glass products is certified by the National Glass Quality Supervision and Inspection Center, with traceable test reports.
Summary of Technical AdvantagesLOW-E glass achieves a balance of "high light transmittance + low emissivity" by precisely controlling the film thickness (5-30 nm) and refractive index. When combined with a hollow structure, it can reduce building energy consumption by over 30%.

Reference for full text summary
As the core material for building energy efficiency, the technical selection of LOW-E glass requires comprehensive consideration of climate, orientation, and cost. Jiangyin Jiaxin Glass Products offers a full-chain solution to the industry through a three-dimensional layout of "coating technology + composite process + customized services," covering products ranging from single-silver to triple-silver and from standard offerings to project-specific customizations. In the future, with the widespread adoption of ultra-low-energy building standards, technological advancements in LOW-E glass will focus on achieving lower emissivity (target ≤0.1) and higher light transmittance (target ≥85%). Jiaxin Glass will continue to invest in research and development to support the building industry in achieving its "dual carbon" goals.

LOW-E玻璃应用案例